Polymethyl methacrylate(PMMA)is an optically transparent thermoplastic with favorable processing conditions.In this study,a series of plastic scintillators are prepared via thermal polymerization,and the impact of PMM...Polymethyl methacrylate(PMMA)is an optically transparent thermoplastic with favorable processing conditions.In this study,a series of plastic scintillators are prepared via thermal polymerization,and the impact of PMMA content on their transparency and pulse shape discrimination(PSD)ability is investigated.The fabricated samples,comprising a polystyrene(PS)-PMMA matrix,30.0 wt%2,5-diphenyloxazole(PPO),and 0.2 wt%9,10-diphenylanthracene(DPA),exhibit high transparency with transmissivity ranging from 70.0 to 90.0%(above 415.0 nm)and demonstrate excellent n/γdiscrimination capability.Transparency increased with increasing PMMA content across the entire visible light spectrum.However,the PSD performance gradually deteriorated when the aromatic matrix was replaced with PMMA.The scintillator containing 20.0 wt%PMMA demonstrated the best stability concerning PSD properties and relative light yields.展开更多
Lead halide perovskite scintillators have recently received extensive research attention owing to their short fluorescence lifetimes,low detection limits,and ease of fabrication compared to traditional scintillators.T...Lead halide perovskite scintillators have recently received extensive research attention owing to their short fluorescence lifetimes,low detection limits,and ease of fabrication compared to traditional scintillators.The nontoxic cerium-doped lead-free perovskites with intrinsically efficient and short lifetime d–f transitions are a prospective replacement for the toxic Pb^(2+).Here,we demonstrated Ce-doped cesium lanthanide chloride perovskites (Cs_(3)LnCl_(6),Ln=Gd,Y,Lu) synthesized through a facile solution method for the first time.These perovskites exhibit blue-violet emission,which arises from Ce 5d→4f transitions.Among three types of Cs_(3)LnCl_(6) perovskites,Ce:Cs_(3)LuCl_(6) exhibited high photoluminescence quantum yield (PLQY) of 82%and a short excited-state lifetime of approximately 34 ns.When utilized as X-ray scintillators,Ce:Cs_(3)LuCl_(6) crystals display a high light yield of 8120 photons per MeV and a low detection limit of 36.8 n Gy air s^(-1).Importantly,the figure of merit (FoM),representing the ratio of light yield to decay time,reaches 239,which is the highest reported value for lead-free perovskite scintillators up to now.Additionally,the fabrication of perovskite/PMMA films was undertaken for practical demonstrations in X-ray imaging,resulting in the attainment of a resolution of up to 8.38 lp/mm.We anticipate that this work will inspire the utilization of Ce-doped Cs_(3)LnCl_(6) perovskites in ultrafast scintillation applications such as high-energy physics,nuclear reaction monitoring,and dynamic X-ray imaging.展开更多
Large-volume liquid scintillator detectors with ultra-low background levels have been widely used to study neutrino physics and search for dark matter.Event vertex and event time are not only useful for event selectio...Large-volume liquid scintillator detectors with ultra-low background levels have been widely used to study neutrino physics and search for dark matter.Event vertex and event time are not only useful for event selection but also essential for the reconstruction of event energy.In this study,four event vertex and event time reconstruction algorithms using charge and time information collected by photomultiplier tubes were analyzed comprehensively.The effects of photomultiplier tube properties were also investigated.The results indicate that the transit time spread is the main effect degrading the vertex reconstruction,while the effect of dark noise is limited.In addition,when the event is close to the detector boundary,the charge information provides better performance for vertex reconstruction than the time information.展开更多
This study presents the design and performance results for compact plastic scintillator strips using a wavelength shifting fiber(WLS-fiber)readout with dimensions of 0.1 m×0.02 m×2 m.This approach was evalua...This study presents the design and performance results for compact plastic scintillator strips using a wavelength shifting fiber(WLS-fiber)readout with dimensions of 0.1 m×0.02 m×2 m.This approach was evaluated as a candidate for a cosmic-ray muon detector for the Taishan Antineutrino Observatory(JUNO-TAO).The strips coupled with 3-inch photomultiplier tubes(PMTs)were measured and compared between the single-end and double-end readout options.Additionally,a strip using the double-end option coupling with a silicon photomultiplier(SiPM)was further evaluated and compared with the results obtained using PMTs.The performance of the strips was determined by a detailed survey along their length with a cosmicray muon after detailed characterization of the 3-inch PMTs and SiPMs.The proposed design employing a compact plastic scintillator strip with WLS-fiber coupling to a SiPM provides a good choice for cosmic-ray muon veto detectors,particularly when detector dimensions must be limited.展开更多
An x-ray scintillator screen with a special structure, functioning as detector and analyser grating, was proposed for collecting the interferogram of differential phase contrast imaging without absorption grating and ...An x-ray scintillator screen with a special structure, functioning as detector and analyser grating, was proposed for collecting the interferogram of differential phase contrast imaging without absorption grating and difficulty of fabrication by a state of the art technique. On the basis of phase grating diffraction, a detecting model of the scintillator screen was built for analysing the phase and absorption information of objects. According to the analysis, a new method of phase retrievals based on two-images and the optimal structure of screen were presented.展开更多
In order to push the grating-based phase contrast imaging system to be used in hospitM and laboratories, this paper designs and develops a novel structure of x-ray scintillator functioning also as an analyser grating,...In order to push the grating-based phase contrast imaging system to be used in hospitM and laboratories, this paper designs and develops a novel structure of x-ray scintillator functioning also as an analyser grating, which has been proposed for grating-based x-ray differential phase contrast imaging. According to this design, the scintillator should have a periodical structure in one dimension with the pitch equaling the period of self-image of the phase grating at the Talbot distance, where one half of the pitch is pixellated and is made of x-ray sensitive fluorescent material, such as CsI(T1), and the remaining part of the pitch is made of x-ray insensitive material, such as silicon. To realize the design, a deep pore array with a high aspect ratio and specially designed grating pattern are successfully manufactured on 5 inch silicon wafer by the photo-assisted electrochemical etching method. The related other problems, such as oxidation-caused geometrical distortion, the filling of CsI(T1) into deep pores and the removal of inside bubbles, have been overcome. Its pixel size, depth and grating pitch are 3 p.m^7.5 ~m, 150 p^m and 3 Ixm, respectively. The microstructure of the scintillator has been examined microscopically and macroscopically by scanning electron microscope and x-ray resolution chart testing, respectively. The preliminary measurements have shown that the proposed scintillator, also functioning as an analyser grating, has been successfully designed and developed.展开更多
The precise vertex reconstruction for large liquid scintillator detectors is essential.A novel machine learning-based method was successfully developed to reconstruct an event vertex in JUNO.In this study,the performa...The precise vertex reconstruction for large liquid scintillator detectors is essential.A novel machine learning-based method was successfully developed to reconstruct an event vertex in JUNO.In this study,the performance of machine learning-based vertex reconstruction was further improved by optimizing the input images of neural networks.By separating the information of different types of PMTs and adding the information of the second hit of PMTs,the vertex resolution was improved by approximately 9.4% at 1 MeV and 9.8% at 11 MeV.展开更多
To reduce the experimental uncertainty in the 235 U resonance energy region and improve the detection efficiency for neutron total cross section measurements compared with those obtained with the neutron total cross s...To reduce the experimental uncertainty in the 235 U resonance energy region and improve the detection efficiency for neutron total cross section measurements compared with those obtained with the neutron total cross section spectrometer(NTOX), a dedicated lithium-containing scintillation detector has been developed on the Back-n beam line at the China Spallation Neutron Source. The Fast Scintillator-based Neutron Total Cross Section(FAST) spectrometer has been designed based on a Cs2Li La Br6(CLLB) scintillator considering the γ-ray flash and neutron environment on the Back-n beam line. The response of the CLLB scintillator to neutrons and γ-rays was evaluated with different 6Li/7 Li abundance ratios using Geant4. The neutron-γdiscrimination performance of the CLLB has been simulated considering different scintillation parameters, physical designs,and light readout modes. A cubic 6Li-enriched( > 90%) CLLB scintillator, which has a thickness of 4-9 mm and side length of no less than 50 mm to cover the Φ 50 mm neutron beam at the spectrometer position, has been proposed coupling to a side readout SiPM array to construct the FAST spectrometer. The developed simulation techniques for neutron-γ discrimination performance could provide technical support for other neutron-induced reaction measurements on the Back-n beam line.展开更多
Plastic scintillators(PSs)embedded with wavelength-shifting fibers are widely used in high-energy particle physics,such as in muon taggers,as well as in medical physics and other applications.In this study,a simulatio...Plastic scintillators(PSs)embedded with wavelength-shifting fibers are widely used in high-energy particle physics,such as in muon taggers,as well as in medical physics and other applications.In this study,a simulation package was built to evaluate the effects of the diameter and layout of optical fibers on the light yield with different configurations.The optimal optical configuration was designed based on simulations and validated using two PS prototypes under certain experimental condi-tions.A top veto tracker(TVT)for the JUNO-TAO experiment,comprising four layers of 160 strips of PS,was designed and evaluated.The threshold was evaluated when the muon tagging efficiency of a PS strip was>99%.The efficiency of three layer out of four layer of TVT is>99%,even with a tagging efficiency of a single strip as low as 97%,using a threshold of 10 photoelectrons and assuming a 40%silicon PM photon detection efficiency.展开更多
In this study,an online detector system based on plastic scintillators is designed to monitor the activity of tritiated water in the liquid effluents of nuclear power plants.The feasibility of the detector is verified...In this study,an online detector system based on plastic scintillators is designed to monitor the activity of tritiated water in the liquid effluents of nuclear power plants.The feasibility of the detector is verified via simulation on Geant4,and the optimal detector structure size is determined.A back-end electronics system is designed and an experimental measurement platform forβ-rays based on a ^(40)KCl solution is constructed.Thirteen ^(40)KC solutions with different activities ranging from 10 to4500 Bq/L are measured,and 1300 V is determined as the optimal operating high voltage of the photomultiplier tubes.A linear fit is performed in 10-min counts,and the maximum linear goodness of fit(R^(2))achieved is 0.9992.Long-term stability measurements are performed for two detectors,one filled with air and the other with a ^(40)KCl solution exhibiting an activity of 2000 Bq/L.The relative deviation of the counts of the detector system every 10 min is 0.998%when the ^(40)KCl solution is used,and the maximum Gaussian R^(2) of the counts is 0.9849.展开更多
High-precision vertex and energy reconstruction are crucial for large liquid scintillator detectors such as that at the Jiangmen Underground Neutrino Observatory(JUNO),especially for the determination of neutrino mass...High-precision vertex and energy reconstruction are crucial for large liquid scintillator detectors such as that at the Jiangmen Underground Neutrino Observatory(JUNO),especially for the determination of neutrino mass ordering by analyzing the energy spectrum of reactor neutrinos.This paper presents a data-driven method to obtain a more realistic and accurate expected PMT response of positron events in JUNO and develops a simultaneous vertex and energy reconstruction method that combines the charge and time information of PMTs.For the JUNO detector,the impact of the vertex inaccuracy on the energy resolution is approximately 0.6%.展开更多
Fast beam range measurements are required to maximize the time available for patient treatment, given that the beam range requires verification with respect to quality assurance to maintain accelerator commissioning s...Fast beam range measurements are required to maximize the time available for patient treatment, given that the beam range requires verification with respect to quality assurance to maintain accelerator commissioning standards and ensure patient safety. A novel beam range monitor based on a plastic scintillator and multi-pixel photon counter (MPPC) arrays is therefore proposed in this paper. The monitor was constructed using 128 plastic scintillator films with a thickness of 1 mm and an active area of 50 × 50 mm^(2). A customized MPPC array read the scintillation light of each film. The advantage of dividing the active detector volume into films is that it intercepts the particle beam and enables direct differential light yield measurement in each film, in addition to depth-light curve generation without the need for image analysis A GEANT4 simulation, including scintillator quenching effects, was implemented, and the results revealed that Birks’ law exhibited a slight little influence on the position of the beam range, only changing the shape and absolute normalization of the Bragg curve, which is appropriate for the calculation of the beam range using the depth-light curve. The performance of the monitor was evaluated using a heavy-ion medical machine in Wuwei City, Gansu Province, China. The beam range measurement accuracy of the monitor was 1 mm, and the maximum difference between the measured and reference ranges was less than0.2%, thus indicating that the monitor can meet clinica carbon ion therapy requirements.展开更多
Traditional plastic scintillator has respectively low gamma energy resolution.Space radiation detection need the plastic scintillator to keep a relatively better energy resolution for gamma.Thus we did experiments to ...Traditional plastic scintillator has respectively low gamma energy resolution.Space radiation detection need the plastic scintillator to keep a relatively better energy resolution for gamma.Thus we did experiments to study how to get it enhanced by adding light guider and chamfer.A 9000 Bq radioactive source 60 Co has been utilized to make the experiment and results came that when keeping other conditions same,the height of poly methyl methacrylate(PMMA)light guider changes from 12 mm to 40 mm and the energy resolutions varied from 72.3%to63.5% respectively.Furthermore,another contrast experiment was made to decide whether plastic scintillator with light guiders or integrated chamfer can get better energy resolution.In conclusion the plastic scintillator with integrated chamfer got 55.0%.Through the study of adding light guider or chamfer to plastic scintillator,the gamma energy resolution has been improved greatly from 72.3%to 55.0%.展开更多
The evolution of lead halide perovskites used for X-ray imaging scintillators has been facilitated by the development of solution-processable semiconductors characterized by large-area,flexible,fast photoresponse.The ...The evolution of lead halide perovskites used for X-ray imaging scintillators has been facilitated by the development of solution-processable semiconductors characterized by large-area,flexible,fast photoresponse.The stability and durability of these new perovskites are insufficient to achieve extended computed tomography scanning times with hard X-rays.In this study,we fabricated a self-assembled CsPbBr_(3)-based scintillator film with a flexible large-area uniform thickness using a new roomtemperature solution-processable method.The sensitivity and responsivity of X-ray photon conversion were quantitatively measured and showed a good linear response relationship suitable for X-ray imaging.We also demonstrated,for the first time,that the self-assembled CsPbBr_(3)-based scintillator has good stability for hard X-ray microtomography.Therefore,such an inexpensive solution-processed semiconductor easily prepared at room temperature can be used as a hard X-ray scintillator and equipped with flexible CsPbBr3-based X-ray detectors.It has great potential in three-dimensional high-resolution phase-contrast X-ray-imaging applications in biomedicine and material science because of its heavy Pb and Br atoms.展开更多
Chinese Spallation Neutron Source(CSNS) has successfully produced its first neutron beam in 28th August 2017. It has been running steadily from March, 2018. According to the construction plan, the engineering material...Chinese Spallation Neutron Source(CSNS) has successfully produced its first neutron beam in 28th August 2017. It has been running steadily from March, 2018. According to the construction plan, the engineering materials diffractometer(EMD) will be installed between 2019–2023. This instrument requires the neutron detectors with the cover area near3 m2in two 90° neutron diffraction angle positions, the neutron detecting efficiency is better than 40%@1A, and the spatial resolution is better than 4 mm×200 mm in horizontal and vertical directions respectively. We have developed a onedimensional position-sensitive neutron detector based on the oblique6Li F/Zn S(Ag) scintillators, wavelength shifting fibers,and Si PMs(silicon photomultipliers) readout. The inhomogeneity of the neutron detection efficiency between each pixel and each detector module, which caused by the inconsistency of the wave-length shifting fibers in collecting scintillation photons, needs to be mitigated before the installation. A performance optimization experiment of the detector modules was carried out on the BL20(beam line 20) of CSNS. Using water sample, the neutron beam with Φ5 mm exit hole was dispersed related evenly into the forward space. According to the neutron counts of each pixel of the detector module, the readout electronics threshold of each pixel is adjusted. Compared with the unadjusted detector module, the inhomogeneity of the detection efficiency for the adjusted one has been improved from 69% to 90%. The test result of the diffraction peak of the standard sample Si showed that the adjusted detector module works well.展开更多
In recent years, the increasing demand of various fields of radiation detection materials has led to intensive researches in scintillation materials 1-2]. The scintillators can absorb high-energy X-ray photons and the...In recent years, the increasing demand of various fields of radiation detection materials has led to intensive researches in scintillation materials 1-2]. The scintillators can absorb high-energy X-ray photons and then convert them into low-energy visible photons, which are widely applied in radiation monitoring, security detection, X-ray astronomy and medical radiology 3"l].展开更多
Non-vanishing electromagnetic properties of neutrinos have been predicted by many theories beyond the Standard Model, and an enhanced neutrino magnetic moment can have profound implications for fundamental physics. Th...Non-vanishing electromagnetic properties of neutrinos have been predicted by many theories beyond the Standard Model, and an enhanced neutrino magnetic moment can have profound implications for fundamental physics. The XENON1T experiment recently detected an excess of electron recoil events in the 1–7 keV energy range, which can be compatible with solar neutrino magnetic moment interaction at a most probable value of μ_(v) = 2.1 × 10^(-11)μ_(B).However, tritium backgrounds or solar axion interaction in this energy window are equally plausible causes.Upcoming multi-tonne noble liquid detectors will test these scenarios more in depth, but will continue to face similar ambiguity. We report a unique capability of future large liquid scintillator detectors to help resolve the potential neutrino magnetic moment scenario. With O(100) kton·year exposure of liquid scintillator to solar neutrinos, a sensitivity of μ_(v) < 10^(-11)μ_(B) can be reached at an energy threshold greater than 40 keV, where no tritium or solar axion events but only neutrino magnetic moment signal is still present.展开更多
An accurate energy calibration of a 5"× 2" BC501A liquid scintillator-based neutron detector by means of photon sources and the unfolding of pulse height spectra are described. The photon responses were measure...An accurate energy calibration of a 5"× 2" BC501A liquid scintillator-based neutron detector by means of photon sources and the unfolding of pulse height spectra are described. The photon responses were measured with 22Na, 137Cs and 54Mn photon sources and simulated using the GRESP code, which was developed at the Physiknlisch Technische Bundesanstalt in Germany. Pulse height spectra produced by three different photon sources were employed to investigate the effects of the unfolding techniques. It was found that the four unfolding codes of the HEPRO and UMG3.3 packages, including GRAVEL, UNFANA, MIEKE and MAXED, performed well with the test spectra and produced generally consistent results. They could therefore be used to obtain neutron energy spectra in toknmak experiments.展开更多
Plastic scintillation detectors based whole body β/γ contamination monitors are developed for use in radiation facilities.This microcontroller-based multi-detector system uses 13 plastic scintillator detectors,with ...Plastic scintillation detectors based whole body β/γ contamination monitors are developed for use in radiation facilities.This microcontroller-based multi-detector system uses 13 plastic scintillator detectors,with minimized dead detection zones,monitoring the whole body,and conforming to the contamination limit prescribed by the regulatory authority.This system has the features for monitoring hands,feet,head,and faceβ/γusing contamination monitors and portal exit monitors.It can detect gamma sources at a dose rate of 10 n Gyh^(-1).The system is calibrated using b sources^(90)Sr/^(90)Y,^(204)Tl,and^(36)Cl,and the efficiency is found to be 29%,22%,and 18%,respectively.Theminimumdetectableβ/γcontaminationis0.15 Bqcm^(-2),which is significantly less than the minimum detection objectives on head,face,hands,and feet.展开更多
Aggregation-induced emission(AIE)is a unique phenomenon where certain organic materials exhibit enhanced luminescence in their aggregated states,overcoming the typical quenching observed in conventional organic materi...Aggregation-induced emission(AIE)is a unique phenomenon where certain organic materials exhibit enhanced luminescence in their aggregated states,overcoming the typical quenching observed in conventional organic materials.Since its discovery in 2001,AIE has driven significant advances in fields like OLEDs and biological imaging,earning recognition in fundamental research.However,its application in high-energy radiation detection remains underexplored.Organic scintillators,though widely used,face challenges such as low light yield and poor radiation attenuation.AIE materials offer promising solutions by improving light yield,response speed,and radiation attenuation.This review summarizes the design strategies behind AIE scintillators and their very recent applications in X-ray,γ-ray,and fast neutron detection.We highlight their advantages in enhancing detection sensitivity,reducing background noise,and achieving high-resolution imaging.By addressing the current challenges,we believe AIE materials will play a pivotal role in advancing future radiation detection and imaging technologies.展开更多
基金supported by the National Natural Science Foundation of China(No.12027813)the fund of National Innovation Center of Radiation Application of China(Nos.KFZC2020020501,KFZC2021010101).
文摘Polymethyl methacrylate(PMMA)is an optically transparent thermoplastic with favorable processing conditions.In this study,a series of plastic scintillators are prepared via thermal polymerization,and the impact of PMMA content on their transparency and pulse shape discrimination(PSD)ability is investigated.The fabricated samples,comprising a polystyrene(PS)-PMMA matrix,30.0 wt%2,5-diphenyloxazole(PPO),and 0.2 wt%9,10-diphenylanthracene(DPA),exhibit high transparency with transmissivity ranging from 70.0 to 90.0%(above 415.0 nm)and demonstrate excellent n/γdiscrimination capability.Transparency increased with increasing PMMA content across the entire visible light spectrum.However,the PSD performance gradually deteriorated when the aromatic matrix was replaced with PMMA.The scintillator containing 20.0 wt%PMMA demonstrated the best stability concerning PSD properties and relative light yields.
基金supported by the National Natural Science Foundation of China (Grant Nos. 22075043, 21875034, 12274075, 62375142)。
文摘Lead halide perovskite scintillators have recently received extensive research attention owing to their short fluorescence lifetimes,low detection limits,and ease of fabrication compared to traditional scintillators.The nontoxic cerium-doped lead-free perovskites with intrinsically efficient and short lifetime d–f transitions are a prospective replacement for the toxic Pb^(2+).Here,we demonstrated Ce-doped cesium lanthanide chloride perovskites (Cs_(3)LnCl_(6),Ln=Gd,Y,Lu) synthesized through a facile solution method for the first time.These perovskites exhibit blue-violet emission,which arises from Ce 5d→4f transitions.Among three types of Cs_(3)LnCl_(6) perovskites,Ce:Cs_(3)LuCl_(6) exhibited high photoluminescence quantum yield (PLQY) of 82%and a short excited-state lifetime of approximately 34 ns.When utilized as X-ray scintillators,Ce:Cs_(3)LuCl_(6) crystals display a high light yield of 8120 photons per MeV and a low detection limit of 36.8 n Gy air s^(-1).Importantly,the figure of merit (FoM),representing the ratio of light yield to decay time,reaches 239,which is the highest reported value for lead-free perovskite scintillators up to now.Additionally,the fabrication of perovskite/PMMA films was undertaken for practical demonstrations in X-ray imaging,resulting in the attainment of a resolution of up to 8.38 lp/mm.We anticipate that this work will inspire the utilization of Ce-doped Cs_(3)LnCl_(6) perovskites in ultrafast scintillation applications such as high-energy physics,nuclear reaction monitoring,and dynamic X-ray imaging.
基金supported by the National Natural Science Foundation of China(Nos.11805294 and 11975021)the China Postdoctoral Science Foundation(2018M631013),the Strategic Priority Research Program of Chinese Academy of Sciences(XDA10010900)+1 种基金the Fundamental Research Funds for the Central Universities,Sun Yatsen University(19lgpy268)in part by the CAS Center for Excellence in Particle Physics(CCEPP).
文摘Large-volume liquid scintillator detectors with ultra-low background levels have been widely used to study neutrino physics and search for dark matter.Event vertex and event time are not only useful for event selection but also essential for the reconstruction of event energy.In this study,four event vertex and event time reconstruction algorithms using charge and time information collected by photomultiplier tubes were analyzed comprehensively.The effects of photomultiplier tube properties were also investigated.The results indicate that the transit time spread is the main effect degrading the vertex reconstruction,while the effect of dark noise is limited.In addition,when the event is close to the detector boundary,the charge information provides better performance for vertex reconstruction than the time information.
基金the National Natural Science Foundation of China(Nos.11875282,11475205 and 12022505)the Strategic Priority Research Program of the Chinese Academy of Sciences(No.XDA10011200)the Youth Innovation Promotion Association of CAS.
文摘This study presents the design and performance results for compact plastic scintillator strips using a wavelength shifting fiber(WLS-fiber)readout with dimensions of 0.1 m×0.02 m×2 m.This approach was evaluated as a candidate for a cosmic-ray muon detector for the Taishan Antineutrino Observatory(JUNO-TAO).The strips coupled with 3-inch photomultiplier tubes(PMTs)were measured and compared between the single-end and double-end readout options.Additionally,a strip using the double-end option coupling with a silicon photomultiplier(SiPM)was further evaluated and compared with the results obtained using PMTs.The performance of the strips was determined by a detailed survey along their length with a cosmicray muon after detailed characterization of the 3-inch PMTs and SiPMs.The proposed design employing a compact plastic scintillator strip with WLS-fiber coupling to a SiPM provides a good choice for cosmic-ray muon veto detectors,particularly when detector dimensions must be limited.
基金supported by the National Natural Science Foundation of China (Grant Nos. 60232090 and 10774102)the Science & Technology Project from Shenzhen Government of China (Grant Nos. 2008340 and 200717)
文摘An x-ray scintillator screen with a special structure, functioning as detector and analyser grating, was proposed for collecting the interferogram of differential phase contrast imaging without absorption grating and difficulty of fabrication by a state of the art technique. On the basis of phase grating diffraction, a detecting model of the scintillator screen was built for analysing the phase and absorption information of objects. According to the analysis, a new method of phase retrievals based on two-images and the optimal structure of screen were presented.
基金supported by the Major Program of the National Natural Science Foundation of China (Grant No. 60532090)
文摘In order to push the grating-based phase contrast imaging system to be used in hospitM and laboratories, this paper designs and develops a novel structure of x-ray scintillator functioning also as an analyser grating, which has been proposed for grating-based x-ray differential phase contrast imaging. According to this design, the scintillator should have a periodical structure in one dimension with the pitch equaling the period of self-image of the phase grating at the Talbot distance, where one half of the pitch is pixellated and is made of x-ray sensitive fluorescent material, such as CsI(T1), and the remaining part of the pitch is made of x-ray insensitive material, such as silicon. To realize the design, a deep pore array with a high aspect ratio and specially designed grating pattern are successfully manufactured on 5 inch silicon wafer by the photo-assisted electrochemical etching method. The related other problems, such as oxidation-caused geometrical distortion, the filling of CsI(T1) into deep pores and the removal of inside bubbles, have been overcome. Its pixel size, depth and grating pitch are 3 p.m^7.5 ~m, 150 p^m and 3 Ixm, respectively. The microstructure of the scintillator has been examined microscopically and macroscopically by scanning electron microscope and x-ray resolution chart testing, respectively. The preliminary measurements have shown that the proposed scintillator, also functioning as an analyser grating, has been successfully designed and developed.
基金supported by the National Natural Science Foundation of China(Nos.11975021,12175257,12175321,11675275,and U1932101)the Guangdong Basic and Applied Basic Research Foundation(No.2021A1515012039)+3 种基金the Strategic Priority Research Program of the Chinese Academy of Sciences(No.XDA10010900)the National College Students Science and Technology Innovation Projectthe Undergraduate Base Scientific Research Project of Sun Yat-sen Universitythe CAS Center for Excellence in Particle Physics(CCEPP).
文摘The precise vertex reconstruction for large liquid scintillator detectors is essential.A novel machine learning-based method was successfully developed to reconstruct an event vertex in JUNO.In this study,the performance of machine learning-based vertex reconstruction was further improved by optimizing the input images of neural networks.By separating the information of different types of PMTs and adding the information of the second hit of PMTs,the vertex resolution was improved by approximately 9.4% at 1 MeV and 9.8% at 11 MeV.
基金supported by the Key Laboratory of Nuclear Data Foundation(No.JCKY2022201C153)National Natural Science Foundation of China(No.11505216),Educational Commission of Hunan Province of China(No.19B488)Natural Science Foundation of Hunan Province of China(Nos.2021JJ40444 and 2020RC3054).
文摘To reduce the experimental uncertainty in the 235 U resonance energy region and improve the detection efficiency for neutron total cross section measurements compared with those obtained with the neutron total cross section spectrometer(NTOX), a dedicated lithium-containing scintillation detector has been developed on the Back-n beam line at the China Spallation Neutron Source. The Fast Scintillator-based Neutron Total Cross Section(FAST) spectrometer has been designed based on a Cs2Li La Br6(CLLB) scintillator considering the γ-ray flash and neutron environment on the Back-n beam line. The response of the CLLB scintillator to neutrons and γ-rays was evaluated with different 6Li/7 Li abundance ratios using Geant4. The neutron-γdiscrimination performance of the CLLB has been simulated considering different scintillation parameters, physical designs,and light readout modes. A cubic 6Li-enriched( > 90%) CLLB scintillator, which has a thickness of 4-9 mm and side length of no less than 50 mm to cover the Φ 50 mm neutron beam at the spectrometer position, has been proposed coupling to a side readout SiPM array to construct the FAST spectrometer. The developed simulation techniques for neutron-γ discrimination performance could provide technical support for other neutron-induced reaction measurements on the Back-n beam line.
基金supported by the School of Physics at Sun Yat-sen University,China
文摘Plastic scintillators(PSs)embedded with wavelength-shifting fibers are widely used in high-energy particle physics,such as in muon taggers,as well as in medical physics and other applications.In this study,a simulation package was built to evaluate the effects of the diameter and layout of optical fibers on the light yield with different configurations.The optimal optical configuration was designed based on simulations and validated using two PS prototypes under certain experimental condi-tions.A top veto tracker(TVT)for the JUNO-TAO experiment,comprising four layers of 160 strips of PS,was designed and evaluated.The threshold was evaluated when the muon tagging efficiency of a PS strip was>99%.The efficiency of three layer out of four layer of TVT is>99%,even with a tagging efficiency of a single strip as low as 97%,using a threshold of 10 photoelectrons and assuming a 40%silicon PM photon detection efficiency.
基金supported by the National Natural Science Foundation of China (No. 12105029)。
文摘In this study,an online detector system based on plastic scintillators is designed to monitor the activity of tritiated water in the liquid effluents of nuclear power plants.The feasibility of the detector is verified via simulation on Geant4,and the optimal detector structure size is determined.A back-end electronics system is designed and an experimental measurement platform forβ-rays based on a ^(40)KCl solution is constructed.Thirteen ^(40)KC solutions with different activities ranging from 10 to4500 Bq/L are measured,and 1300 V is determined as the optimal operating high voltage of the photomultiplier tubes.A linear fit is performed in 10-min counts,and the maximum linear goodness of fit(R^(2))achieved is 0.9992.Long-term stability measurements are performed for two detectors,one filled with air and the other with a ^(40)KCl solution exhibiting an activity of 2000 Bq/L.The relative deviation of the counts of the detector system every 10 min is 0.998%when the ^(40)KCl solution is used,and the maximum Gaussian R^(2) of the counts is 0.9849.
基金supported by the National Key R&D Program of China(No.2018YFA0404100)the Strategic Priority Research Program of the Chinese Academy of Sciences(No.12175257)+1 种基金the National Natural Science Foundation of China(No.12175257)the Science Foundation of High-Level Talents of Wuyi University(No.2021AL027).
文摘High-precision vertex and energy reconstruction are crucial for large liquid scintillator detectors such as that at the Jiangmen Underground Neutrino Observatory(JUNO),especially for the determination of neutrino mass ordering by analyzing the energy spectrum of reactor neutrinos.This paper presents a data-driven method to obtain a more realistic and accurate expected PMT response of positron events in JUNO and develops a simultaneous vertex and energy reconstruction method that combines the charge and time information of PMTs.For the JUNO detector,the impact of the vertex inaccuracy on the energy resolution is approximately 0.6%.
基金supported by the National Natural Science Foundation of China (Nos.11675232 and 12175286)。
文摘Fast beam range measurements are required to maximize the time available for patient treatment, given that the beam range requires verification with respect to quality assurance to maintain accelerator commissioning standards and ensure patient safety. A novel beam range monitor based on a plastic scintillator and multi-pixel photon counter (MPPC) arrays is therefore proposed in this paper. The monitor was constructed using 128 plastic scintillator films with a thickness of 1 mm and an active area of 50 × 50 mm^(2). A customized MPPC array read the scintillation light of each film. The advantage of dividing the active detector volume into films is that it intercepts the particle beam and enables direct differential light yield measurement in each film, in addition to depth-light curve generation without the need for image analysis A GEANT4 simulation, including scintillator quenching effects, was implemented, and the results revealed that Birks’ law exhibited a slight little influence on the position of the beam range, only changing the shape and absolute normalization of the Bragg curve, which is appropriate for the calculation of the beam range using the depth-light curve. The performance of the monitor was evaluated using a heavy-ion medical machine in Wuwei City, Gansu Province, China. The beam range measurement accuracy of the monitor was 1 mm, and the maximum difference between the measured and reference ranges was less than0.2%, thus indicating that the monitor can meet clinica carbon ion therapy requirements.
基金supported by the National Natural Science Foundation of China including Research on the Technology of Fast Neutron Location Sensitive Detector Based on GEM and Data Acquisition(No.11575073)the Space Neutron Telescope Detection Technology(No.11775114)
文摘Traditional plastic scintillator has respectively low gamma energy resolution.Space radiation detection need the plastic scintillator to keep a relatively better energy resolution for gamma.Thus we did experiments to study how to get it enhanced by adding light guider and chamfer.A 9000 Bq radioactive source 60 Co has been utilized to make the experiment and results came that when keeping other conditions same,the height of poly methyl methacrylate(PMMA)light guider changes from 12 mm to 40 mm and the energy resolutions varied from 72.3%to63.5% respectively.Furthermore,another contrast experiment was made to decide whether plastic scintillator with light guiders or integrated chamfer can get better energy resolution.In conclusion the plastic scintillator with integrated chamfer got 55.0%.Through the study of adding light guider or chamfer to plastic scintillator,the gamma energy resolution has been improved greatly from 72.3%to 55.0%.
基金supported by National Natural Science Foundation of China (No. 12175127)Natural Science Foundation of Shandong Province,China (No. ZR2020MA088)
文摘The evolution of lead halide perovskites used for X-ray imaging scintillators has been facilitated by the development of solution-processable semiconductors characterized by large-area,flexible,fast photoresponse.The stability and durability of these new perovskites are insufficient to achieve extended computed tomography scanning times with hard X-rays.In this study,we fabricated a self-assembled CsPbBr_(3)-based scintillator film with a flexible large-area uniform thickness using a new roomtemperature solution-processable method.The sensitivity and responsivity of X-ray photon conversion were quantitatively measured and showed a good linear response relationship suitable for X-ray imaging.We also demonstrated,for the first time,that the self-assembled CsPbBr_(3)-based scintillator has good stability for hard X-ray microtomography.Therefore,such an inexpensive solution-processed semiconductor easily prepared at room temperature can be used as a hard X-ray scintillator and equipped with flexible CsPbBr3-based X-ray detectors.It has great potential in three-dimensional high-resolution phase-contrast X-ray-imaging applications in biomedicine and material science because of its heavy Pb and Br atoms.
基金Project supported by the National Natural Science Foundation of China (Grant Nos. 11975255 and 11875273)Guangdong Basic and Applied Basic Research Foundation (Grant No. 2020B1515120025)。
文摘Chinese Spallation Neutron Source(CSNS) has successfully produced its first neutron beam in 28th August 2017. It has been running steadily from March, 2018. According to the construction plan, the engineering materials diffractometer(EMD) will be installed between 2019–2023. This instrument requires the neutron detectors with the cover area near3 m2in two 90° neutron diffraction angle positions, the neutron detecting efficiency is better than 40%@1A, and the spatial resolution is better than 4 mm×200 mm in horizontal and vertical directions respectively. We have developed a onedimensional position-sensitive neutron detector based on the oblique6Li F/Zn S(Ag) scintillators, wavelength shifting fibers,and Si PMs(silicon photomultipliers) readout. The inhomogeneity of the neutron detection efficiency between each pixel and each detector module, which caused by the inconsistency of the wave-length shifting fibers in collecting scintillation photons, needs to be mitigated before the installation. A performance optimization experiment of the detector modules was carried out on the BL20(beam line 20) of CSNS. Using water sample, the neutron beam with Φ5 mm exit hole was dispersed related evenly into the forward space. According to the neutron counts of each pixel of the detector module, the readout electronics threshold of each pixel is adjusted. Compared with the unadjusted detector module, the inhomogeneity of the detection efficiency for the adjusted one has been improved from 69% to 90%. The test result of the diffraction peak of the standard sample Si showed that the adjusted detector module works well.
文摘In recent years, the increasing demand of various fields of radiation detection materials has led to intensive researches in scintillation materials 1-2]. The scintillators can absorb high-energy X-ray photons and then convert them into low-energy visible photons, which are widely applied in radiation monitoring, security detection, X-ray astronomy and medical radiology 3"l].
基金Supported by the Strategic Priority Research Program of the Chinese Academy of Sciences (Grant No. XDA10010800)the Double First Class Start-up Fund (WF220442603) provided by Shanghai Jiao Tong Universitysupport from the CAS Center for Excellence in Particle Physics (CCEPP)。
文摘Non-vanishing electromagnetic properties of neutrinos have been predicted by many theories beyond the Standard Model, and an enhanced neutrino magnetic moment can have profound implications for fundamental physics. The XENON1T experiment recently detected an excess of electron recoil events in the 1–7 keV energy range, which can be compatible with solar neutrino magnetic moment interaction at a most probable value of μ_(v) = 2.1 × 10^(-11)μ_(B).However, tritium backgrounds or solar axion interaction in this energy window are equally plausible causes.Upcoming multi-tonne noble liquid detectors will test these scenarios more in depth, but will continue to face similar ambiguity. We report a unique capability of future large liquid scintillator detectors to help resolve the potential neutrino magnetic moment scenario. With O(100) kton·year exposure of liquid scintillator to solar neutrinos, a sensitivity of μ_(v) < 10^(-11)μ_(B) can be reached at an energy threshold greater than 40 keV, where no tritium or solar axion events but only neutrino magnetic moment signal is still present.
基金supported by the State Key Development Program for Basic Research of China (Nos. 2008CB717803, 2009GB107001,2007CB209903)the Research Fund for the Doctoral Program of Higher Education of China (No. 200610011023)National Natural Science Foundation of China (No. 10875002)
文摘An accurate energy calibration of a 5"× 2" BC501A liquid scintillator-based neutron detector by means of photon sources and the unfolding of pulse height spectra are described. The photon responses were measured with 22Na, 137Cs and 54Mn photon sources and simulated using the GRESP code, which was developed at the Physiknlisch Technische Bundesanstalt in Germany. Pulse height spectra produced by three different photon sources were employed to investigate the effects of the unfolding techniques. It was found that the four unfolding codes of the HEPRO and UMG3.3 packages, including GRAVEL, UNFANA, MIEKE and MAXED, performed well with the test spectra and produced generally consistent results. They could therefore be used to obtain neutron energy spectra in toknmak experiments.
文摘Plastic scintillation detectors based whole body β/γ contamination monitors are developed for use in radiation facilities.This microcontroller-based multi-detector system uses 13 plastic scintillator detectors,with minimized dead detection zones,monitoring the whole body,and conforming to the contamination limit prescribed by the regulatory authority.This system has the features for monitoring hands,feet,head,and faceβ/γusing contamination monitors and portal exit monitors.It can detect gamma sources at a dose rate of 10 n Gyh^(-1).The system is calibrated using b sources^(90)Sr/^(90)Y,^(204)Tl,and^(36)Cl,and the efficiency is found to be 29%,22%,and 18%,respectively.Theminimumdetectableβ/γcontaminationis0.15 Bqcm^(-2),which is significantly less than the minimum detection objectives on head,face,hands,and feet.
基金financial support from National Natural Science Foundation of China(No.22175156)the Fundamental Research Funds for the Central Universities,China University of Geosciences(Wuhan)(No.162301202692).
文摘Aggregation-induced emission(AIE)is a unique phenomenon where certain organic materials exhibit enhanced luminescence in their aggregated states,overcoming the typical quenching observed in conventional organic materials.Since its discovery in 2001,AIE has driven significant advances in fields like OLEDs and biological imaging,earning recognition in fundamental research.However,its application in high-energy radiation detection remains underexplored.Organic scintillators,though widely used,face challenges such as low light yield and poor radiation attenuation.AIE materials offer promising solutions by improving light yield,response speed,and radiation attenuation.This review summarizes the design strategies behind AIE scintillators and their very recent applications in X-ray,γ-ray,and fast neutron detection.We highlight their advantages in enhancing detection sensitivity,reducing background noise,and achieving high-resolution imaging.By addressing the current challenges,we believe AIE materials will play a pivotal role in advancing future radiation detection and imaging technologies.