期刊文献+
共找到68篇文章
< 1 2 4 >
每页显示 20 50 100
Optical transmittance and pulse shape discrimination of polystyrene/poly(methyl methacrylate)-based plastic scintillators
1
作者 Yi-Yao Liang Ying-Du Liu +2 位作者 Pu-Sen Wang Jie Bao Xiao-Ping Ouyang 《Nuclear Science and Techniques》 2025年第1期94-102,共9页
Polymethyl methacrylate(PMMA)is an optically transparent thermoplastic with favorable processing conditions.In this study,a series of plastic scintillators are prepared via thermal polymerization,and the impact of PMM... Polymethyl methacrylate(PMMA)is an optically transparent thermoplastic with favorable processing conditions.In this study,a series of plastic scintillators are prepared via thermal polymerization,and the impact of PMMA content on their transparency and pulse shape discrimination(PSD)ability is investigated.The fabricated samples,comprising a polystyrene(PS)-PMMA matrix,30.0 wt%2,5-diphenyloxazole(PPO),and 0.2 wt%9,10-diphenylanthracene(DPA),exhibit high transparency with transmissivity ranging from 70.0 to 90.0%(above 415.0 nm)and demonstrate excellent n/γdiscrimination capability.Transparency increased with increasing PMMA content across the entire visible light spectrum.However,the PSD performance gradually deteriorated when the aromatic matrix was replaced with PMMA.The scintillator containing 20.0 wt%PMMA demonstrated the best stability concerning PSD properties and relative light yields. 展开更多
关键词 Neutron detection Plastic scintillation Pulse shape discrimination Polymethyl-methacrylate POLYSTYRENE
在线阅读 下载PDF
Lead-free Ce-doped perovskite scintillators with high figure of merit
2
作者 Xiang Li Haixia Cui +4 位作者 Yanxi Zhong Xiaoxi Zhou Shuhong Xu Shujuan Liu Chunlei Wang 《Journal of Energy Chemistry》 SCIE EI CAS CSCD 2024年第12期74-82,共9页
Lead halide perovskite scintillators have recently received extensive research attention owing to their short fluorescence lifetimes,low detection limits,and ease of fabrication compared to traditional scintillators.T... Lead halide perovskite scintillators have recently received extensive research attention owing to their short fluorescence lifetimes,low detection limits,and ease of fabrication compared to traditional scintillators.The nontoxic cerium-doped lead-free perovskites with intrinsically efficient and short lifetime d–f transitions are a prospective replacement for the toxic Pb^(2+).Here,we demonstrated Ce-doped cesium lanthanide chloride perovskites (Cs_(3)LnCl_(6),Ln=Gd,Y,Lu) synthesized through a facile solution method for the first time.These perovskites exhibit blue-violet emission,which arises from Ce 5d→4f transitions.Among three types of Cs_(3)LnCl_(6) perovskites,Ce:Cs_(3)LuCl_(6) exhibited high photoluminescence quantum yield (PLQY) of 82%and a short excited-state lifetime of approximately 34 ns.When utilized as X-ray scintillators,Ce:Cs_(3)LuCl_(6) crystals display a high light yield of 8120 photons per MeV and a low detection limit of 36.8 n Gy air s^(-1).Importantly,the figure of merit (FoM),representing the ratio of light yield to decay time,reaches 239,which is the highest reported value for lead-free perovskite scintillators up to now.Additionally,the fabrication of perovskite/PMMA films was undertaken for practical demonstrations in X-ray imaging,resulting in the attainment of a resolution of up to 8.38 lp/mm.We anticipate that this work will inspire the utilization of Ce-doped Cs_(3)LnCl_(6) perovskites in ultrafast scintillation applications such as high-energy physics,nuclear reaction monitoring,and dynamic X-ray imaging. 展开更多
关键词 Lead-free perovskite Short lifetime scintillators X-ray imaging
在线阅读 下载PDF
Event vertex and time reconstruction in large-volume liquid scintillator detectors 被引量:8
3
作者 Zi-Yuan Li Yu-Mei Zhang +9 位作者 Guo-Fu Cao Zi-Yan Deng Gui-Hong Huang Wei-Dong Li Tao Lin Liang-Jian Wen Miao Yu Jia-Heng Zou Wu-Ming Luo Zheng-Yun You 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2021年第5期51-62,共12页
Large-volume liquid scintillator detectors with ultra-low background levels have been widely used to study neutrino physics and search for dark matter.Event vertex and event time are not only useful for event selectio... Large-volume liquid scintillator detectors with ultra-low background levels have been widely used to study neutrino physics and search for dark matter.Event vertex and event time are not only useful for event selection but also essential for the reconstruction of event energy.In this study,four event vertex and event time reconstruction algorithms using charge and time information collected by photomultiplier tubes were analyzed comprehensively.The effects of photomultiplier tube properties were also investigated.The results indicate that the transit time spread is the main effect degrading the vertex reconstruction,while the effect of dark noise is limited.In addition,when the event is close to the detector boundary,the charge information provides better performance for vertex reconstruction than the time information. 展开更多
关键词 JUNO Liquid scintillator detector Neutrino experiment Vertex reconstruction Time reconstruction
在线阅读 下载PDF
Performance of compact plastic scintillator strips with wavelength shifting fibers using a photomultiplier tube or silicon photomultiplier readout 被引量:5
4
作者 Min Li Zhi‑Min Wang +5 位作者 Cai‑Mei Liu Pei‑Zhi Lu Guang Luo Yuen‑Keung Hor Jin‑Chang Liu Chang‑Gen Yang 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2023年第2期178-189,共12页
This study presents the design and performance results for compact plastic scintillator strips using a wavelength shifting fiber(WLS-fiber)readout with dimensions of 0.1 m×0.02 m×2 m.This approach was evalua... This study presents the design and performance results for compact plastic scintillator strips using a wavelength shifting fiber(WLS-fiber)readout with dimensions of 0.1 m×0.02 m×2 m.This approach was evaluated as a candidate for a cosmic-ray muon detector for the Taishan Antineutrino Observatory(JUNO-TAO).The strips coupled with 3-inch photomultiplier tubes(PMTs)were measured and compared between the single-end and double-end readout options.Additionally,a strip using the double-end option coupling with a silicon photomultiplier(SiPM)was further evaluated and compared with the results obtained using PMTs.The performance of the strips was determined by a detailed survey along their length with a cosmicray muon after detailed characterization of the 3-inch PMTs and SiPMs.The proposed design employing a compact plastic scintillator strip with WLS-fiber coupling to a SiPM provides a good choice for cosmic-ray muon veto detectors,particularly when detector dimensions must be limited. 展开更多
关键词 PMT SIPM Plastic scintillator WLS-fiber Muon detection Efficiency
在线阅读 下载PDF
A new method of detecting interferogram in differential phase-contrast imaging system based on special structured x-ray scintillator screen 被引量:6
5
作者 刘鑫 郭金川 牛憨笨 《Chinese Physics B》 SCIE EI CAS CSCD 2010年第7期193-197,共5页
An x-ray scintillator screen with a special structure, functioning as detector and analyser grating, was proposed for collecting the interferogram of differential phase contrast imaging without absorption grating and ... An x-ray scintillator screen with a special structure, functioning as detector and analyser grating, was proposed for collecting the interferogram of differential phase contrast imaging without absorption grating and difficulty of fabrication by a state of the art technique. On the basis of phase grating diffraction, a detecting model of the scintillator screen was built for analysing the phase and absorption information of objects. According to the analysis, a new method of phase retrievals based on two-images and the optimal structure of screen were presented. 展开更多
关键词 differential phase contrast x-ray scintillator screen phase retrieval
在线阅读 下载PDF
Development of x-ray scintillator functioning also as an analyser grating used in grating-based x-ray differential phase contrast imaging 被引量:4
6
作者 雷耀虎 刘鑫 +2 位作者 郭金川 赵志刚 牛憨笨 《Chinese Physics B》 SCIE EI CAS CSCD 2011年第4期222-227,共6页
In order to push the grating-based phase contrast imaging system to be used in hospitM and laboratories, this paper designs and develops a novel structure of x-ray scintillator functioning also as an analyser grating,... In order to push the grating-based phase contrast imaging system to be used in hospitM and laboratories, this paper designs and develops a novel structure of x-ray scintillator functioning also as an analyser grating, which has been proposed for grating-based x-ray differential phase contrast imaging. According to this design, the scintillator should have a periodical structure in one dimension with the pitch equaling the period of self-image of the phase grating at the Talbot distance, where one half of the pitch is pixellated and is made of x-ray sensitive fluorescent material, such as CsI(T1), and the remaining part of the pitch is made of x-ray insensitive material, such as silicon. To realize the design, a deep pore array with a high aspect ratio and specially designed grating pattern are successfully manufactured on 5 inch silicon wafer by the photo-assisted electrochemical etching method. The related other problems, such as oxidation-caused geometrical distortion, the filling of CsI(T1) into deep pores and the removal of inside bubbles, have been overcome. Its pixel size, depth and grating pitch are 3 p.m^7.5 ~m, 150 p^m and 3 Ixm, respectively. The microstructure of the scintillator has been examined microscopically and macroscopically by scanning electron microscope and x-ray resolution chart testing, respectively. The preliminary measurements have shown that the proposed scintillator, also functioning as an analyser grating, has been successfully designed and developed. 展开更多
关键词 scintillator screen pore arrays oxidation CsI(T1) analyser grating
在线阅读 下载PDF
Improvement of machine learning-based vertex reconstruction for large liquid scintillator detectors with multiple types of PMTs 被引量:3
7
作者 Zi-Yuan Li Zhen Qian +6 位作者 Jie-Han He Wei He Cheng-Xin Wu Xun-Ye Cai Zheng-Yun You Yu-Mei Zhang Wu-Ming Luo 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2022年第7期93-102,共10页
The precise vertex reconstruction for large liquid scintillator detectors is essential.A novel machine learning-based method was successfully developed to reconstruct an event vertex in JUNO.In this study,the performa... The precise vertex reconstruction for large liquid scintillator detectors is essential.A novel machine learning-based method was successfully developed to reconstruct an event vertex in JUNO.In this study,the performance of machine learning-based vertex reconstruction was further improved by optimizing the input images of neural networks.By separating the information of different types of PMTs and adding the information of the second hit of PMTs,the vertex resolution was improved by approximately 9.4% at 1 MeV and 9.8% at 11 MeV. 展开更多
关键词 JUNO Liquid scintillator detector Neutrino experiment Vertex reconstruction Machine learning
在线阅读 下载PDF
Conceptual design of a Cs2LiLaBr6 scintillator‑based neutron total cross section spectrometer on the back‑n beam line at CSNS 被引量:3
8
作者 Da‑Jun Zhao Song Feng +6 位作者 Pin‑Jing Cheng Rong Liu Wen Luo Hao‑Qiang Wang Jie‑Ming Xue Kun Zhu Bo Zheng 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2023年第1期23-32,共10页
To reduce the experimental uncertainty in the 235 U resonance energy region and improve the detection efficiency for neutron total cross section measurements compared with those obtained with the neutron total cross s... To reduce the experimental uncertainty in the 235 U resonance energy region and improve the detection efficiency for neutron total cross section measurements compared with those obtained with the neutron total cross section spectrometer(NTOX), a dedicated lithium-containing scintillation detector has been developed on the Back-n beam line at the China Spallation Neutron Source. The Fast Scintillator-based Neutron Total Cross Section(FAST) spectrometer has been designed based on a Cs2Li La Br6(CLLB) scintillator considering the γ-ray flash and neutron environment on the Back-n beam line. The response of the CLLB scintillator to neutrons and γ-rays was evaluated with different 6Li/7 Li abundance ratios using Geant4. The neutron-γdiscrimination performance of the CLLB has been simulated considering different scintillation parameters, physical designs,and light readout modes. A cubic 6Li-enriched( > 90%) CLLB scintillator, which has a thickness of 4-9 mm and side length of no less than 50 mm to cover the Φ 50 mm neutron beam at the spectrometer position, has been proposed coupling to a side readout SiPM array to construct the FAST spectrometer. The developed simulation techniques for neutron-γ discrimination performance could provide technical support for other neutron-induced reaction measurements on the Back-n beam line. 展开更多
关键词 Neutron total cross section CLLB scintillator GEANT4 Pulse shape discrimination(PSD)
在线阅读 下载PDF
Design optimization of plastic scintillators with wavelength-shifting fibers and silicon photomultiplier readouts in the top veto tracker of the JUNO-TAO experiment 被引量:2
9
作者 Guang Luo Y.K.Hor +10 位作者 Pei-Zhi Lu Zhi-Min Wang Ru-Hui Li Min Li Yi-Chen Li Liang Zhan Wei Wang Yue-Huan Wei Yu Chen Xiang Xiao Feng-Peng An 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2023年第7期99-112,共14页
Plastic scintillators(PSs)embedded with wavelength-shifting fibers are widely used in high-energy particle physics,such as in muon taggers,as well as in medical physics and other applications.In this study,a simulatio... Plastic scintillators(PSs)embedded with wavelength-shifting fibers are widely used in high-energy particle physics,such as in muon taggers,as well as in medical physics and other applications.In this study,a simulation package was built to evaluate the effects of the diameter and layout of optical fibers on the light yield with different configurations.The optimal optical configuration was designed based on simulations and validated using two PS prototypes under certain experimental condi-tions.A top veto tracker(TVT)for the JUNO-TAO experiment,comprising four layers of 160 strips of PS,was designed and evaluated.The threshold was evaluated when the muon tagging efficiency of a PS strip was>99%.The efficiency of three layer out of four layer of TVT is>99%,even with a tagging efficiency of a single strip as low as 97%,using a threshold of 10 photoelectrons and assuming a 40%silicon PM photon detection efficiency. 展开更多
关键词 Plastic scintillator WLS fiber Light yield Optical transmission performance Muon tagging efficiency JUNO-TAO
在线阅读 下载PDF
Design and preliminary test of tritiated water online detector system based on plastic scintillators 被引量:2
10
作者 Chun-Hui Dong Kai-Yong Liao +2 位作者 Rui-Yang Xu Hong-Wu Liu Qing-Xian Zhang 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2022年第10期68-78,共11页
In this study,an online detector system based on plastic scintillators is designed to monitor the activity of tritiated water in the liquid effluents of nuclear power plants.The feasibility of the detector is verified... In this study,an online detector system based on plastic scintillators is designed to monitor the activity of tritiated water in the liquid effluents of nuclear power plants.The feasibility of the detector is verified via simulation on Geant4,and the optimal detector structure size is determined.A back-end electronics system is designed and an experimental measurement platform forβ-rays based on a ^(40)KCl solution is constructed.Thirteen ^(40)KC solutions with different activities ranging from 10 to4500 Bq/L are measured,and 1300 V is determined as the optimal operating high voltage of the photomultiplier tubes.A linear fit is performed in 10-min counts,and the maximum linear goodness of fit(R^(2))achieved is 0.9992.Long-term stability measurements are performed for two detectors,one filled with air and the other with a ^(40)KCl solution exhibiting an activity of 2000 Bq/L.The relative deviation of the counts of the detector system every 10 min is 0.998%when the ^(40)KCl solution is used,and the maximum Gaussian R^(2) of the counts is 0.9849. 展开更多
关键词 Tritiated water GEANT4 Plastic scintillator Electronics system
在线阅读 下载PDF
Data-driven simultaneous vertex and energy reconstruction for large liquid scintillator detectors 被引量:1
11
作者 Gui-Hong Huang Wei Jiang +2 位作者 Liang-Jian Wen Yi-Fang Wang Wu-Ming Luo 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2023年第6期103-113,共11页
High-precision vertex and energy reconstruction are crucial for large liquid scintillator detectors such as that at the Jiangmen Underground Neutrino Observatory(JUNO),especially for the determination of neutrino mass... High-precision vertex and energy reconstruction are crucial for large liquid scintillator detectors such as that at the Jiangmen Underground Neutrino Observatory(JUNO),especially for the determination of neutrino mass ordering by analyzing the energy spectrum of reactor neutrinos.This paper presents a data-driven method to obtain a more realistic and accurate expected PMT response of positron events in JUNO and develops a simultaneous vertex and energy reconstruction method that combines the charge and time information of PMTs.For the JUNO detector,the impact of the vertex inaccuracy on the energy resolution is approximately 0.6%. 展开更多
关键词 JUNO Liquid scintillator detector Neutrino experiment Vertex reconstruction Energy reconstruction
在线阅读 下载PDF
A beam range monitor based on scintillator and multi-pixel photon counter arrays for heavy ions therapy 被引量:1
12
作者 Wei Wang Xiao-Xiao Yuan Xiao-Hong Cai 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2022年第10期11-21,共11页
Fast beam range measurements are required to maximize the time available for patient treatment, given that the beam range requires verification with respect to quality assurance to maintain accelerator commissioning s... Fast beam range measurements are required to maximize the time available for patient treatment, given that the beam range requires verification with respect to quality assurance to maintain accelerator commissioning standards and ensure patient safety. A novel beam range monitor based on a plastic scintillator and multi-pixel photon counter (MPPC) arrays is therefore proposed in this paper. The monitor was constructed using 128 plastic scintillator films with a thickness of 1 mm and an active area of 50 × 50 mm^(2). A customized MPPC array read the scintillation light of each film. The advantage of dividing the active detector volume into films is that it intercepts the particle beam and enables direct differential light yield measurement in each film, in addition to depth-light curve generation without the need for image analysis A GEANT4 simulation, including scintillator quenching effects, was implemented, and the results revealed that Birks’ law exhibited a slight little influence on the position of the beam range, only changing the shape and absolute normalization of the Bragg curve, which is appropriate for the calculation of the beam range using the depth-light curve. The performance of the monitor was evaluated using a heavy-ion medical machine in Wuwei City, Gansu Province, China. The beam range measurement accuracy of the monitor was 1 mm, and the maximum difference between the measured and reference ranges was less than0.2%, thus indicating that the monitor can meet clinica carbon ion therapy requirements. 展开更多
关键词 Beam range scintillator Multi-pixel photon counter(MPPC) Depth-light curve
在线阅读 下载PDF
Improvement on Gamma Energy Resolution of Plastic Scintillator by Adding PMMA Light Guider or Chamfer
13
作者 Wang Yi Wei Zhiyong +2 位作者 Fang Meihua Guo Yipan Yu Junhao 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI CSCD 2018年第S1期63-67,共5页
Traditional plastic scintillator has respectively low gamma energy resolution.Space radiation detection need the plastic scintillator to keep a relatively better energy resolution for gamma.Thus we did experiments to ... Traditional plastic scintillator has respectively low gamma energy resolution.Space radiation detection need the plastic scintillator to keep a relatively better energy resolution for gamma.Thus we did experiments to study how to get it enhanced by adding light guider and chamfer.A 9000 Bq radioactive source 60 Co has been utilized to make the experiment and results came that when keeping other conditions same,the height of poly methyl methacrylate(PMMA)light guider changes from 12 mm to 40 mm and the energy resolutions varied from 72.3%to63.5% respectively.Furthermore,another contrast experiment was made to decide whether plastic scintillator with light guiders or integrated chamfer can get better energy resolution.In conclusion the plastic scintillator with integrated chamfer got 55.0%.Through the study of adding light guider or chamfer to plastic scintillator,the gamma energy resolution has been improved greatly from 72.3%to 55.0%. 展开更多
关键词 ENERGY RESOLUTION PLASTIC scintillator light guider ENERGY spectrum
在线阅读 下载PDF
New flexible CsPbBr_(3)-based scintillator for X-ray tomography
14
作者 Zhi-Wei Lü Gong-Xiang Wei +6 位作者 Han-Qiu Wang Yu Guan Ning Jiang Yun-Yan Liu Zhao Li Hua Qin Hui-Qiang Liu 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2022年第8期34-44,共11页
The evolution of lead halide perovskites used for X-ray imaging scintillators has been facilitated by the development of solution-processable semiconductors characterized by large-area,flexible,fast photoresponse.The ... The evolution of lead halide perovskites used for X-ray imaging scintillators has been facilitated by the development of solution-processable semiconductors characterized by large-area,flexible,fast photoresponse.The stability and durability of these new perovskites are insufficient to achieve extended computed tomography scanning times with hard X-rays.In this study,we fabricated a self-assembled CsPbBr_(3)-based scintillator film with a flexible large-area uniform thickness using a new roomtemperature solution-processable method.The sensitivity and responsivity of X-ray photon conversion were quantitatively measured and showed a good linear response relationship suitable for X-ray imaging.We also demonstrated,for the first time,that the self-assembled CsPbBr_(3)-based scintillator has good stability for hard X-ray microtomography.Therefore,such an inexpensive solution-processed semiconductor easily prepared at room temperature can be used as a hard X-ray scintillator and equipped with flexible CsPbBr3-based X-ray detectors.It has great potential in three-dimensional high-resolution phase-contrast X-ray-imaging applications in biomedicine and material science because of its heavy Pb and Br atoms. 展开更多
关键词 X-ray scintillator X-ray illumination Computed tomography CsPbBr_(3)-based film perovskite Solution-processable semiconductor
在线阅读 下载PDF
Performance optimization of scintillator neutron detectors for EMD in CSNS
15
作者 蔡小杰 于潜 +5 位作者 黄畅 唐彬 周诗慧 王小胡 岳秀萍 孙志嘉 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第11期207-213,共7页
Chinese Spallation Neutron Source(CSNS) has successfully produced its first neutron beam in 28th August 2017. It has been running steadily from March, 2018. According to the construction plan, the engineering material... Chinese Spallation Neutron Source(CSNS) has successfully produced its first neutron beam in 28th August 2017. It has been running steadily from March, 2018. According to the construction plan, the engineering materials diffractometer(EMD) will be installed between 2019–2023. This instrument requires the neutron detectors with the cover area near3 m2in two 90° neutron diffraction angle positions, the neutron detecting efficiency is better than 40%@1A, and the spatial resolution is better than 4 mm×200 mm in horizontal and vertical directions respectively. We have developed a onedimensional position-sensitive neutron detector based on the oblique6Li F/Zn S(Ag) scintillators, wavelength shifting fibers,and Si PMs(silicon photomultipliers) readout. The inhomogeneity of the neutron detection efficiency between each pixel and each detector module, which caused by the inconsistency of the wave-length shifting fibers in collecting scintillation photons, needs to be mitigated before the installation. A performance optimization experiment of the detector modules was carried out on the BL20(beam line 20) of CSNS. Using water sample, the neutron beam with Φ5 mm exit hole was dispersed related evenly into the forward space. According to the neutron counts of each pixel of the detector module, the readout electronics threshold of each pixel is adjusted. Compared with the unadjusted detector module, the inhomogeneity of the detection efficiency for the adjusted one has been improved from 69% to 90%. The test result of the diffraction peak of the standard sample Si showed that the adjusted detector module works well. 展开更多
关键词 scintillator neutron detector silicon photomultipliers wavelength shifting fiber LiF/ZnS scintil-lator detection efficiency inhomogeneity
在线阅读 下载PDF
Tunable Radioluminescence Perovskite Nanocrystal Scintillators
16
作者 LI Lin 《材料导报》 EI CAS CSCD 北大核心 2018年第23期I0001-I0002,共2页
In recent years, the increasing demand of various fields of radiation detection materials has led to intensive researches in scintillation materials 1-2]. The scintillators can absorb high-energy X-ray photons and the... In recent years, the increasing demand of various fields of radiation detection materials has led to intensive researches in scintillation materials 1-2]. The scintillators can absorb high-energy X-ray photons and then convert them into low-energy visible photons, which are widely applied in radiation monitoring, security detection, X-ray astronomy and medical radiology 3"l]. 展开更多
关键词 TUNABLE RADIOLUMINESCENCE PEROVSKITE Nanocrystal scintillatorS
在线阅读 下载PDF
Unambiguously Resolving the Potential Neutrino Magnetic Moment Signal at Large Liquid Scintillator Detectors
17
作者 Ziping Ye Feiyang Zhang +1 位作者 Donglian Xu Jianglai Liu 《Chinese Physics Letters》 SCIE CAS CSCD 2021年第11期18-22,共5页
Non-vanishing electromagnetic properties of neutrinos have been predicted by many theories beyond the Standard Model, and an enhanced neutrino magnetic moment can have profound implications for fundamental physics. Th... Non-vanishing electromagnetic properties of neutrinos have been predicted by many theories beyond the Standard Model, and an enhanced neutrino magnetic moment can have profound implications for fundamental physics. The XENON1T experiment recently detected an excess of electron recoil events in the 1–7 keV energy range, which can be compatible with solar neutrino magnetic moment interaction at a most probable value of μ_(v) = 2.1 × 10^(-11)μ_(B).However, tritium backgrounds or solar axion interaction in this energy window are equally plausible causes.Upcoming multi-tonne noble liquid detectors will test these scenarios more in depth, but will continue to face similar ambiguity. We report a unique capability of future large liquid scintillator detectors to help resolve the potential neutrino magnetic moment scenario. With O(100) kton·year exposure of liquid scintillator to solar neutrinos, a sensitivity of μ_(v) < 10^(-11)μ_(B) can be reached at an energy threshold greater than 40 keV, where no tritium or solar axion events but only neutrino magnetic moment signal is still present. 展开更多
关键词 Unambiguously Resolving the Potential Neutrino Magnetic Moment Signal at Large Liquid scintillator Detectors
在线阅读 下载PDF
Calibration and Unfolding of the Pulse Height Spectra of Liquid Scintillator-Based Neutron Detectors Using Photon Sources 被引量:4
18
作者 谢旭飞 袁熙 +3 位作者 张兴 樊铁栓 陈金象 李湘庆 《Plasma Science and Technology》 SCIE EI CAS CSCD 2012年第6期553-557,共5页
An accurate energy calibration of a 5"× 2" BC501A liquid scintillator-based neutron detector by means of photon sources and the unfolding of pulse height spectra are described. The photon responses were measure... An accurate energy calibration of a 5"× 2" BC501A liquid scintillator-based neutron detector by means of photon sources and the unfolding of pulse height spectra are described. The photon responses were measured with 22Na, 137Cs and 54Mn photon sources and simulated using the GRESP code, which was developed at the Physiknlisch Technische Bundesanstalt in Germany. Pulse height spectra produced by three different photon sources were employed to investigate the effects of the unfolding techniques. It was found that the four unfolding codes of the HEPRO and UMG3.3 packages, including GRAVEL, UNFANA, MIEKE and MAXED, performed well with the test spectra and produced generally consistent results. They could therefore be used to obtain neutron energy spectra in toknmak experiments. 展开更多
关键词 liquid scintillation detector CALIBRATION pulse height spectra unfolding methods
在线阅读 下载PDF
Design and development of a plastic scintillator based whole body β/γ contamination monitoring system 被引量:2
19
作者 Vaishali M.Thakur Amit Jain +4 位作者 P.Ashokkumar Rekha Anilkumar Pravin Sawant Probal Chaudhury L.M.Chaudhari 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2021年第5期33-42,共10页
Plastic scintillation detectors based whole body β/γ contamination monitors are developed for use in radiation facilities.This microcontroller-based multi-detector system uses 13 plastic scintillator detectors,with ... Plastic scintillation detectors based whole body β/γ contamination monitors are developed for use in radiation facilities.This microcontroller-based multi-detector system uses 13 plastic scintillator detectors,with minimized dead detection zones,monitoring the whole body,and conforming to the contamination limit prescribed by the regulatory authority.This system has the features for monitoring hands,feet,head,and faceβ/γusing contamination monitors and portal exit monitors.It can detect gamma sources at a dose rate of 10 n Gyh^(-1).The system is calibrated using b sources^(90)Sr/^(90)Y,^(204)Tl,and^(36)Cl,and the efficiency is found to be 29%,22%,and 18%,respectively.Theminimumdetectableβ/γcontaminationis0.15 Bqcm^(-2),which is significantly less than the minimum detection objectives on head,face,hands,and feet. 展开更多
关键词 Plastic scintillation detector Contamination monitor MICROCONTROLLER Minimum Detection Objective(MDO) Minimum Detection Concentration(MDC)
在线阅读 下载PDF
Aggregation‑Induced Emissive Scintillators:A New Frontier for Radiation Detection and Imaging
20
作者 Xinyi Li Jiafu Yu +2 位作者 Yinghao Fan Yuting Gao Guangda Niu 《Nano-Micro Letters》 2025年第7期190-205,共16页
Aggregation-induced emission(AIE)is a unique phenomenon where certain organic materials exhibit enhanced luminescence in their aggregated states,overcoming the typical quenching observed in conventional organic materi... Aggregation-induced emission(AIE)is a unique phenomenon where certain organic materials exhibit enhanced luminescence in their aggregated states,overcoming the typical quenching observed in conventional organic materials.Since its discovery in 2001,AIE has driven significant advances in fields like OLEDs and biological imaging,earning recognition in fundamental research.However,its application in high-energy radiation detection remains underexplored.Organic scintillators,though widely used,face challenges such as low light yield and poor radiation attenuation.AIE materials offer promising solutions by improving light yield,response speed,and radiation attenuation.This review summarizes the design strategies behind AIE scintillators and their very recent applications in X-ray,γ-ray,and fast neutron detection.We highlight their advantages in enhancing detection sensitivity,reducing background noise,and achieving high-resolution imaging.By addressing the current challenges,we believe AIE materials will play a pivotal role in advancing future radiation detection and imaging technologies. 展开更多
关键词 Aggregation-induced emission scintillators Radiation detection Radiation imaging
在线阅读 下载PDF
上一页 1 2 4 下一页 到第
使用帮助 返回顶部