期刊文献+
共找到7,374篇文章
< 1 2 250 >
每页显示 20 50 100
In situ compression and X-ray computed tomography of flow battery electrodes 被引量:1
1
作者 Rhodri Jervis Matt D.R.Kok +6 位作者 Tobias P.Neville Quentin Meyer Leon D.Brown Francesco Iacoviello Jeff T.Gostick Dan J.L.Brett Paul R.Shearing 《Journal of Energy Chemistry》 SCIE EI CAS CSCD 2018年第5期1353-1361,共9页
Redox flow batteries offer a potential solution to an increase in renewable energy generation on the grid by offering long-term, large-scale storage and regulation of power. However, they are currently un- derutilised... Redox flow batteries offer a potential solution to an increase in renewable energy generation on the grid by offering long-term, large-scale storage and regulation of power. However, they are currently un- derutilised due to cost and performance issues, many of which are linked to the microstructure of the porous carbon electrodes used. Here, for the first time, we offer a detailed study of the in situ effects of compression on a commercially available carbon felt electrode. Visualisation of electrode structure us- ing X-ray computed tomography shows the non-linear way that these materials compress and various metrics are used to elucidate the changes in porosity, pore size distribution and tortuosity factor under compressions from 0%-90%. 展开更多
关键词 Redox flow battery x-ray computed tomography Compression Carbon felt RFB
在线阅读 下载PDF
Optimization-based image reconstruction in x-ray computed tomography by sparsity exploitation of local continuity and nonlocal spatial self-similarity 被引量:1
2
作者 张瀚铭 王林元 +3 位作者 李磊 闫镔 蔡爱龙 胡国恩 《Chinese Physics B》 SCIE EI CAS CSCD 2016年第7期557-565,共9页
The additional sparse prior of images has been the subject of much research in problems of sparse-view computed tomography(CT) reconstruction. A method employing the image gradient sparsity is often used to reduce t... The additional sparse prior of images has been the subject of much research in problems of sparse-view computed tomography(CT) reconstruction. A method employing the image gradient sparsity is often used to reduce the sampling rate and is shown to remove the unwanted artifacts while preserve sharp edges, but may cause blocky or patchy artifacts.To eliminate this drawback, we propose a novel sparsity exploitation-based model for CT image reconstruction. In the presented model, the sparse representation and sparsity exploitation of both gradient and nonlocal gradient are investigated.The new model is shown to offer the potential for better results by introducing a similarity prior information of the image structure. Then, an effective alternating direction minimization algorithm is developed to optimize the objective function with a robust convergence result. Qualitative and quantitative evaluations have been carried out both on the simulation and real data in terms of accuracy and resolution properties. The results indicate that the proposed method can be applied for achieving better image-quality potential with the theoretically expected detailed feature preservation. 展开更多
关键词 computed tomography image reconstruction sparsity exploitation nonlocal gradient
在线阅读 下载PDF
Simultaneous fluorescence and Compton scattering computed tomography based on linear polarization X-ray
3
作者 Zhi-Jun Chi Hong-Ze Zhang +7 位作者 Jin Lin Xuan-Qi Zhang Hao Ding Qi-Li Tian Zhi Zhang Ying-Chao Du Wen-Hui Huang Chuan-Xiang Tang 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第10期41-50,共10页
Purpose To propose a method for simultaneous fluorescence and Compton scattering computed tomography by using linearly polarized X-rays.Methods Monte Carlo simulations were adopted to demonstrate the feasibility of th... Purpose To propose a method for simultaneous fluorescence and Compton scattering computed tomography by using linearly polarized X-rays.Methods Monte Carlo simulations were adopted to demonstrate the feasibility of the proposed method.In the simulations,the phantom is a polytetrafluoroethylene cylinder inside which are cylindrical columns containing aluminum,water,and gold(Au)-loaded water solutions with Au concentrations ranging between 0.5 and 4.0 wt%,and a parallel-hole collimator imaging geometry was adopted.The light source was modeled based on a Thomson scattering X-ray source.The phantom images for both imaging modalities were reconstructed using a maximumlikelihood expectation maximization algorithm.Results Both the X-ray fluorescence computed tomography(XFCT)and Compton scattering computed tomography(CSCT)images of the phantom were accurately reconstructed.A similar attenuation contrast problem for the different cylindrical columns in the phantom can be resolved in the XFCT and CSCT images.The interplay between XFCT and CSCT was analyzed,and the contrast-to-noise ratio(CNR)of the reconstruction was improved by correcting for the mutual influence between the two imaging modalities.Compared with K-edge subtraction imaging,XFCT exhibits a CNR advantage for the phantom.Conclusion Simultaneous XFCT and CSCT can be realized by using linearly polarized X-rays.The synergy between the two imaging modalities would have an important application in cancer radiation therapy. 展开更多
关键词 x-ray fluorescence computed tomography Compton scattering computed tomography Linear polarization Thomson scattering x-ray source Monte Carlo simulation
在线阅读 下载PDF
Seeing through Materials:X-Ray Imaging Using Computed Tomography 被引量:1
4
作者 Yisheng Miao Chengpeng Xue +2 位作者 Xuelong Wu Zhongyao Li Junsheng Wang 《Journal of Beijing Institute of Technology》 EI CAS 2023年第4期494-516,共23页
X-ray computed tomography(XCT)has recently emerged as a powerful tool for characterizing the evolution of microstructure during phase transformation in three dimensional(3D)such as dendritic solidification of alloys.T... X-ray computed tomography(XCT)has recently emerged as a powerful tool for characterizing the evolution of microstructure during phase transformation in three dimensional(3D)such as dendritic solidification of alloys.This paper briefly reviews the recent advances in the in-situ observation of aluminium alloys,magnesium alloys and nickel-based superalloys during solidification using laboratory XCT and synchrotron X-ray sources.The focus is on the growth kinetics of dendrites,porosity and secondary phases.In addition,in-situ characterization during the loading and corrosion process is also discussed. 展开更多
关键词 x-ray computed tomography(XCT) SYNCHROTRON DENDRITE POROSITY ALLOYS
在线阅读 下载PDF
The diagnostic yield for computed tomography pulmonary angiography in patients with anticoagulation
5
作者 Payush Chatta Brian Diep +4 位作者 Jakrin Kewcharoen Daniel Rossie Cory Toomasian Purvi Parwani Dmitry Abramov 《World Journal of Emergency Medicine》 SCIE CAS CSCD 2024年第4期251-255,共5页
BACKGROUND:Patients who present to the emergency department(ED)for suspected pulmonary embolism(PE)are often on active oral anticoagulation(AC).However,the diagnostic yield of computed tomography pulmonary angiography... BACKGROUND:Patients who present to the emergency department(ED)for suspected pulmonary embolism(PE)are often on active oral anticoagulation(AC).However,the diagnostic yield of computed tomography pulmonary angiography(CTPA)in screening for PE in patients who present on AC has not been well characterized.We aim to investigate the diagnostic yield of CTPA in diagnosing PE depending on AC status.METHODS:We reviewed and analyzed the electronic medical records of patients who underwent CTPA for PE at a university hospital ED from June 1,2019,to March 25,2022.Primary outcome was the incidence of PE on CTPA depending on baseline AC status and indication for AC.RESULTS:Of 2,846 patients,242 were on AC for a history of venous thromboembolism(VTE),210 were on AC for other indications,and 2,394 were not on AC.The incidence of PE on CTPA was significantly lower in patients on AC for other indications(5.7%)when compared to patients on AC for prior VTE(24.3%)and patients not on AC at presentation(9.8%)(P<0.001).In multivariable analysis among the whole cohort,AC was associated with a positive CTPA(odds ratio[OR]0.26,95%confidence interval[CI]:0.15-0.45,P<0.001).CONCLUSION:The incidence of PE among patients undergoing CTPA in the ED is lower in patients previously on AC for indications other than VTE when compared to those not on AC or those on AC for history of VTE.AC status and indication for AC may affect pre-test probability of a positive CTPA,and AC status therefore warrants consideration as part of future diagnostic algorithms among patients with suspected PE. 展开更多
关键词 Pulmonary embolism computed tomography pulmonary angiography Emergency department ANTICOAGULATION
在线阅读 下载PDF
NON-INVASIVE IMAGING OF CORONARY ARTERY WITH 16-SLICE SPIRAL COMPUTED TOMOGRAPHY 被引量:6
6
作者 Zhu-huaZhang Zheng-yuJin +14 位作者 Dong-jingLi Song-baiLin Shu-yangZhang Ling-yanKong YunWang Lin-huiWang Wen-minZhao Wen-binMou Li-RenZhang Wen-lingZhu ChaoNi HuaRen Hong-quanYu QiMiao QiFang 《Chinese Medical Sciences Journal》 CAS CSCD 2004年第3期174-179,共6页
To evaluate the value of 16-slice spiral CT in the demonstration of coronary artery and in the diagnose of coronary artery stenosis. Methods Plain and enhanced CT scans were performed with a 16-slice CT scanner (Sensa... To evaluate the value of 16-slice spiral CT in the demonstration of coronary artery and in the diagnose of coronary artery stenosis. Methods Plain and enhanced CT scans were performed with a 16-slice CT scanner (Sensation 16, Siemens, Germany) in 230 patients with suspected coronary heart disease (CHD). Parameters of the plain scan were: 120 kV, 133 mA, slice col-limation 16 mm×1.5 mm, rotation time 0.42 seconds, increment 1.5 mm, and slice width 3 mm. Parameters of the enhanced scan were: 120 kV, 500 mA, slice collimation 16 mm×0.75 mm, rotation time 0.42 seconds, increment 0.5 mm, and slice width 1 mm. Enhanced CT scan was performed with a rapid intravenous injection of 100 mL iothalamate meglumine (Ultravist) (370 mgI/mL) or Omnipaque (350 mgI/mL) and 30 mL 0.9% NaCl chaser bolus at a flow rate of 3.5 mL/s. Calcium scoring with plain scan images and two and three dimensional reconstruction with enhanced scan images were made in all cases, among which 30 cases underwent conventional coronary angiography. Demonstration of coronary arteries and their stenosis were evaluated and the factors that might influence the image quality were analyzed. Results Coronary calcium scores were calculated and coronary artery was demonstrated in our study. In the evaluationof image quality with volume rendering technique (VRT) images, 78.3% of the images were of the first class, 12.2% the sec-ond class, and 9.6% the third class. Multi-planar reconstruction (MPR) and maximal intensity projection (MIP) were better than VRT in the demonstration of small branches. The image quality was related to the heart rate, with or without arrhythmia, and breath-hold ability of patients. Comparative study of the stenosis of coronary arteries in 30 cases showed that the sensi-tivity and specificity of 16-slice coronary CT angiography (CTA) to diagnose significant stenosis were 95.8% and 94.8% resp-ectively. Conclusion As a non-invasive and quick method, 16-slice coronary CTA is sensitive and specific to diagnose the stenosis of coronary arteries and can be used as a screening method in the diagnosis of CHD. 展开更多
关键词 ANGIOGRAPHY tomography x-ray computed coronary artery
在线阅读 下载PDF
Perihematomal Perfusion Typing and Spot Sign of Acute Intracerebral Hemorrhage with Multimode Computed Tomography: A Preliminary Study 被引量:4
7
作者 Xin-yi Hou Pei-yi Gao 《Chinese Medical Sciences Journal》 CAS CSCD 2014年第3期139-143,共5页
Objective To explore the perihematomal perfusion typing and spot sign on computed tomography angiography(CTA) source images in order to assist in individualizing therapeutic decisions for patients with intracerebral h... Objective To explore the perihematomal perfusion typing and spot sign on computed tomography angiography(CTA) source images in order to assist in individualizing therapeutic decisions for patients with intracerebral hemorrhage by possibly forecasting perihematomal ischemia and hematoma enlargement. Methods We examined 58 patients with spontaneous intracerebral hemorrhage by computed tomography perfusion and CTA within 6 hours after symptom onset. Hematoma volumes were determined from non-contrast CT images and compared between first and second CT images. The perfusion of hematoma region and perihematoma region was evaluated for presence or absence of the perihematomal penumbra. Three kinds of perihematoma perfusion typing were defined according to the perfusion of hematoma region and perihematoma region. CTA source images was reviewed to make sure presence or absence of the spot sign. Results Finally, 53 patients(34 males, 19 females) were enrolled in our study according to exclusion criteria. Finally, 21 patients were classified into the normal group, 23 patients were classified into the mild group, and 9 patients were classified into the severe group. There were significant differences in hematoma size between the presence and absence of the perihematomal penumbra group(P<0.05). Thirteen(24.5%) patients presented with spot sign. Hematoma expansion occurred in 15(28.3%) patients on follow-up. In which 12 patients were with spot sign. Sensitivity, specificity, positive predictive value, and negative predictive value for expansion were 80.0%, 97.4%, 92.3%, and 92.5%, respectively. Conclusion In acute intracerebral hemorrhage patients, the perihematoma perfusion typing and CTA spot sign provide more radiological information that might assist in individualizing therapeutic decisions for patients by possibly forecasting perihematomal ischemia and hematoma enlargement. 展开更多
关键词 intracerebral hemorrhage computed tomography perfusion computed tomography angiography
在线阅读 下载PDF
Enhancement of photoacoustic tomography in the tissue with speed-of-sound variance using ultrasound computed tomography 被引量:1
8
作者 程任翔 陶超 刘晓峻 《Chinese Physics B》 SCIE EI CAS CSCD 2015年第11期63-69,共7页
The speed-of-sound variance will decrease the imaging quality of photoacoustic tomography in acoustically inhomo- geneous tissue. In this study, ultrasound computed tomography is combined with photoacoustic tomography... The speed-of-sound variance will decrease the imaging quality of photoacoustic tomography in acoustically inhomo- geneous tissue. In this study, ultrasound computed tomography is combined with photoacoustic tomography to enhance the photoacoustic tomography in this situation. The speed-of-sound information is recovered by ultrasound computed to- mography. Then, an improved delay-and-sum method is used to reconstruct the image from the photoacoustic signals. The simulation results validate that the proposed method can obtain a better photoacoustic tomography than the conventional method when the speed-of-sound variance is increased. In addition, the influences of the speed-of-sound variance and the fan-angle on the image quality are quantitatively explored to optimize the image scheme. The proposed method has a good performance even when the speed-of-sound variance reaches 14.2%. Furthermore, an optimized fan angle is revealed, which can keep the good image quality with a low cost of hardware. This study has a potential value in extending the biomedical application of photoacoustic tomography. 展开更多
关键词 photoacoustic tomography speed of sound ultrasound computed tomography
在线阅读 下载PDF
Feasibility and accuracy of coronary imaging in elderly patients using the 64-row multi-detector computed tomography: a correlation study with conventional coronary angiography 被引量:4
9
作者 Chee Khoon LIEW Sze Piaw CHIN +6 位作者 Tiong Kiam ONG Seyfarth Tobias Yean Yip FONG Choon Kiat ANG Houng Bang LIEW Rapaee ANNUAR Kui Hian SIM 《Journal of Geriatric Cardiology》 SCIE CAS CSCD 2006年第1期9-14,共6页
Background Elderly patients generally have higher occurrence of coronary calcification, increased heart rate and difficulty with prolonged breath-holding. The aim of our study was to investigate the feasibility and ac... Background Elderly patients generally have higher occurrence of coronary calcification, increased heart rate and difficulty with prolonged breath-holding. The aim of our study was to investigate the feasibility and accuracy of using 64-row multi-detector computed tomography (MDCT) in the assessment of coronary artery stenoses in elderly patients. Methods One hundred and fifty two patients with suspected or known coronary artery disease were divided into 4 groups according to their age (Group A: 40-49 years,n=34; Group B: 50-59 years, n=57; Group C: 60-69 years, n=48; Group D: 70 years and above; n=13). Coronary CT angiography (CTA) using a 64-row MDCT was performed and the findings were compared with that of conventional coronary angiography (CCA).Using axial images, multi-planar reconstructions (MPR) and maximum intensity projections (MIP), coronary segments of lumen diameter = 1.5mm were analyzed for the presence of significant stenosis (= 50% ). Results Percentages of poor image quality from coronary CTA preventing reliable correlations with CCA were 21%, 14%, 19% and 62% in Groups A to D respectively. Patients in Group D had significantly higher calcium scores compared with the other groups (P<0.001). In patients where CTA images were of acceptable quality, percentages of accurate correlations with CCA were 89.8%, 93.4%, 86.6% and 78.0% for Groups A to D respectively.There were no significant difference in serum creatinine, heart rate and contrast volume between the 4 groups. Conclusions The 64-row MDCT coronary angiography was less accurate and feasible for patients aged 70 years or above due to heavy coronary calcification and inability to perform a satisfactory breath-hold. However, a high diagnostic accuracy with the MDCT is possible in patients aged less than 70 years. 展开更多
关键词 computed tomography ANGIOGRAPHY CORONARY ARTERY disease ELDERLY
在线阅读 下载PDF
Ultrasonic Computed Tomography Imaging Method of Concrete Materials Based on Simulated Annealing Genetic Algorithm 被引量:4
10
作者 李秋锋 王禹 +2 位作者 刘荣梅 顾伟 敖峰 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI CSCD 2015年第3期341-347,共7页
Stability and accuracy of the imaging results are still unmet practical demands for ultrasonic computed tomography(CT)of concrete material.To address these issues,a CT technique based on simulated annealing genetic al... Stability and accuracy of the imaging results are still unmet practical demands for ultrasonic computed tomography(CT)of concrete material.To address these issues,a CT technique based on simulated annealing genetic algorithm(SAGA)is presented in this work.Firstly,a natural weight matrix with clear physical meaning is introduced in the inverse algorithm and then a quadric broadening objective function is formed according to the propagation characteristics of ultrasound in concrete.After that,the simulated annealing(SA)searching is added to speed up the inverse process and to improve the convergence and stability of the algorithm.Finally,the optimal inverse imaging results have been achieved by variable ectopic adaptive genetic algorithm.The numerical simulation experiments have shown that the usage of the correct priori information and the excellent characteristic of SAGA in searching the global minimum value of the function have produced accurate and effective results with stable numerical values.The imaging resolution is improved and the imagining results reflecting the inner defections of the tested objects are more reliable and accurate. 展开更多
关键词 CONCRETE materials computed tomography(CT)imaging
在线阅读 下载PDF
Non-enhanced Low-tube-voltage High-pitch Dual-source Computed Tomography with Sinogram Affirmed Iterative Reconstruction Algorithm of the Abdomen and Pelvis 被引量:3
11
作者 Hao Sun Hua-dan Xue +5 位作者 Zheng-yu Jin Xuan Wang Yu Chen Yong-lan He Da-ming Zhang Liang Zhu 《Chinese Medical Sciences Journal》 CAS CSCD 2014年第4期214-220,共7页
Objective To investigate the image quality, radiation dose and diagnostic value of the low-tube-voltage high-pitch dual-source computed tomography(DSCT) with sinogram affirmed iterative reconstruction(SAFIRE) for non-... Objective To investigate the image quality, radiation dose and diagnostic value of the low-tube-voltage high-pitch dual-source computed tomography(DSCT) with sinogram affirmed iterative reconstruction(SAFIRE) for non-enhanced abdominal and pelvic scans. Methods This institutional review board-approved prospective study included 64 patients who gave written informed consent for additional abdominal and pelvic scan with DSCT in the period from November to December 2012. The patients underwent standard non-enhanced CT scans(protocol 1) [tube voltage of 120 k Vp/pitch of 0.9/filtered back-projection(FBP) reconstruction] followed by high-pitch non-enhanced CT scans(protocol 2)(100 k Vp/3.0/SAFIRE). The total scan time, mean CT number, signal-to-noise ratio(SNR), image quality, lesion detectability and radiation dose were compared between the two protocols. Results The total scan time of protocol 2 was significantly shorter than that of protocol 1(1.4±0.1 seconds vs. 7.6±0.6 seconds, P<0.001). There was no significant difference between protocol 1 and protocol 2 in mean CT number of all organs(liver, 55.4±6.3 HU vs. 56.1±6.8 HU, P=0.214; pancreas, 43.6±5.9 HU vs. 43.7±5.8 HU, P=0.785; spleen, 47.9±3.9 HU vs. 49.4±4.3 HU, P=0.128; kidney, 32.2±2.3 HU vs. 33.1±2.3 HU, P=0.367; abdominal aorta, 44.8±5.6 HU vs. 45.0±5.5 HU, P=0.499; psoas muscle, 50.7±4.1 HU vs. 50.3±4.5 HU, P=0.279). SNR on images of protocol 2 was higher than that of protocol 1(liver, 5.0±1.2 vs. 4.5±1.1, P<0.001; pancreas, 4.0±1.0 vs. 3.6±0.8, P<0.001; spleen, 4.7±1.0 vs. 4.1±0.9, P<0.001; kidney, 3.1±0.6 vs. 2.8±0.6, P<0.001; abdominal aorta, 4.1±1.0 vs. 3.8±1.0, P<0.001; psoas muscle, 4.5±1.1 vs. 4.3±1.2, P=0.012). The overall image noise of protocol 2 was lower than that of protocol1(9.8±3.1 HU vs. 11.1±3.0 HU, P<0.001). Image quality of protocol 2 was good but lower than that of protocol 1(4.1±0.7 vs. 4.6±0.5, P<0.001). Protocol 2 perceived 229 of 234 lesions(97.9%) that were detected in protocol 1 in the abdomen and pelvis. Radiation dose of protocol 2 was lower than that of protocol 1(4.4±0.4 m Sv vs. 7.3±2.4 m Sv, P<0.001) and the mean dose reduction was 41.4%. Conclusion The high-pitch DSCT with SAFIRE can shorten scan time and reduce radiation dose while preserving image quality in non-enhanced abdominal and pelvic scans. 展开更多
关键词 high PITCH dual-source computed tomography iterative reconstruction imagequality radiation DOSE
在线阅读 下载PDF
Multislice computed tomography angiography in the diagnosis of coronary artery disease 被引量:7
12
作者 Zhong-Hua Sun Yan Cao Hua-Feng Li 《Journal of Geriatric Cardiology》 SCIE CAS CSCD 2011年第2期104-113,共10页
Multislice CT angiography represents one of the most exciting technological revolutions in cardiac imaging and it has been increasingly used in the diagnosis of coronary artery disease. Rapid improvements in multislic... Multislice CT angiography represents one of the most exciting technological revolutions in cardiac imaging and it has been increasingly used in the diagnosis of coronary artery disease. Rapid improvements in multislice CT scanners over the last decade have allowed this technique to become a potentially effective alternative to invasive coronary angiography in patients with suspected coronary artery disease. High diagnostic value has been achieved with multislice CT angiography with use of 64- and more slice CT scanners. In addition, multislice CT angiography shows accurate detection and analysis of coronary calcium, characterization of coronary plaques, as well as prediction of the disease progression and major cardiac events. Thus, patients can benefit from multislice CT angiography that provides a rapid and accurate diagnosis while avoiding unnecessary invasive coronary angiography procedures. The aim of this article is present an overview of the clinical applications of multislice CT angiography in coronary artery disease with a focus on the diagnostic accuracy of coronary artery disease; prognostic value of coronary artery disease with regard to the prediction of major cardiac events; detection and quantification of coronary calcium and characterization of coronary plaques. Limitations of multislice CT angiography in coronary artery disease are also briefly discussed, and future directions are highlighted. 展开更多
关键词 coronary artery disease PLAQUE DIAGNOSIS multislice computed tomography ANGIOGRAPHY
在线阅读 下载PDF
Comparison of 16 slice multi-detector computed tomography and breath hold 3D magnetic resonance angiography in the detection of coronary stenosis 被引量:2
13
作者 Xin LIU Zulong CAI Youquan CAI Shaohong ZHAO Ningyu AN Yuangui GAO 《Journal of Geriatric Cardiology》 SCIE CAS CSCD 2006年第1期24-28,共5页
Objective To compare 16-slice multi-detector spiral computed tomography (MDCT) and breathhold 3D magnetic resonance (MR) coronary angiography in the visualization of coronary arteries and the accuracy of detecting sig... Objective To compare 16-slice multi-detector spiral computed tomography (MDCT) and breathhold 3D magnetic resonance (MR) coronary angiography in the visualization of coronary arteries and the accuracy of detecting significant (> 50%) coronary stenoses in patients with suspected coronary artery disease. Methods Forty patients were examined by 16-slice CT (GE, Lightspeedl6)and MR (GE,Twinspeed) within 3 days; 31 of them underwent conventional coronary angiography (CAG) within 2 weeks after CT and MR scan. CT was performed with 16× 1.25 mm detector collimation, 0.5 s rotation time and images were reconstructed at 60%-75% of the cardiac cycle. MR was performed with breath hold 3D FIESTA (TR4.0 ms, TE1.7 ms, flip angle 65, slice thickness 3 mm, FOV 280 mm, matrix 256× 192). Mean heart rate was 63 ± 5.8 bpm and β-blocker was used in 24 patients. MR and CT image quality was evaluated in 9 coronary segments (RCA1, RCA2, RCA3, LM, LAD1, LAD2, LAD3, LCX1, LCX2) using a four-point grading scale.Sensitivity, specificity, positive predictive value, negative predictive value and accuracy were calculated for detection of significant stenosis using CAG as the gold standard. Results 16-slice CT showed higher image quality in most coronary segments except RCA2.Forty-three segments were diagnosed as significant stenosis by CAG, 36 and 27 of these were correctly detected by CT and MR respectively. Sensitivity, specificity, positive predictive value, and negative predictive value of 16-slice CT and MR for detecting significant stenosis were 83 %, 84 %, 49 %, 97 % and 63 %, 90 %, 55 %, 93 %, respectively. Conclusion Sixteen-slice CT showed higher image quality in most coronary segments excepted for middle RCA. 16-slice CT had higher sensitivity than MR for detection of coronary significant stenosis, whereas MR had higher specificity than CT. Both CT and MR showed high negative predictive value,which is useful for excluding coronary stenosis in symptomatic patients. 展开更多
关键词 computed tomography magnetic resonance imaging CORONARY ARTERY disease ANGIOGRAPHY
在线阅读 下载PDF
An algorithm for computed tomography image reconstruction from limited-view projections 被引量:5
14
作者 王林元 李磊 +3 位作者 闫镔 江成顺 王浩宇 包尚联 《Chinese Physics B》 SCIE EI CAS CSCD 2010年第8期642-647,共6页
With the development of the compressive sensing theory, the image reconstruction from the projections viewed in limited angles is one of the hot problems in the research of computed tomography technology. This paper d... With the development of the compressive sensing theory, the image reconstruction from the projections viewed in limited angles is one of the hot problems in the research of computed tomography technology. This paper develops an iterative algorithm for image reconstruction, which can fit the most cases. This method gives an image reconstruction flow with the difference image vector, which is based on the concept that the difference image vector between the reconstructed and the reference image is sparse enough. Then the l1-norm minimization method is used to reconstruct the difference vector to recover the image for flat subjects in limited angles. The algorithm has been tested with a thin planar phantom and a real object in limited-view projection data. Moreover, all the studies showed the satisfactory results in accuracy at a rather high reconstruction speed. 展开更多
关键词 limited-view problem computed tomography image reconstruction algorithms reconstruction-reference difference algorithm adaptive steepest descent-projection onto convex sets algorithm
在线阅读 下载PDF
Three-dimensional visualization of soil pore structure using computed tomography 被引量:1
15
作者 Qiaoling Han Xibo Zhou +2 位作者 Lei Liu Yandong Zhao Yue Zhao 《Journal of Forestry Research》 SCIE CAS CSCD 2019年第3期1053-1061,共9页
The geometric and spatial characteristics of pore structures determine the permeability and water retention of soils, which have important effects on soil functional diversity and ecological restoration. Until recentl... The geometric and spatial characteristics of pore structures determine the permeability and water retention of soils, which have important effects on soil functional diversity and ecological restoration. Until recently, there have not been tools and methods to visually and quantitatively describe the characteristics of soil pores. To solve this problem, this research reconstructs the geometry and spatial distribution of soil pores by the marching cubes method, texture mapping method and the ray casting method widely used in literature. The objectives were to explore an optimal method for three-dimensional visualization of soil pore structure by comparing the robustness of the three methods on soil CT images with single pore structure and porosity ranging from low (2–5%) to high (12–18%), and to evaluate the reconstruction performance of the three methods with different geometric features. The results demonstrate that there are aliases (jagged edges) and deficiency at the boundaries of the model reconstructed by the marching cubes method and pore volumes are smaller than the ground truth, whereas the results of the texture mapping method lack the details of pore structures. For all the soil images, the ray casting method is preferable since it better preserves the pore characteristics of the ground truth. Furthermore, the ray casting method produced the best soil pore model with higher rendering speed and lower memory consumption. Therefore, the ray casting method provides a more advanced method for visualization of pore structures and provides an optional technique for the study of the transport of moisture and the exchange of air in soil. 展开更多
关键词 Soil PORE STRUCTURE x-ray computed tomography Three-dimensional reconstruction PORE VISUALIZATION
在线阅读 下载PDF
Assessment of Coronary Stents by 64-slice Computed Tomography: In-stent Lumen Visibility and Patency 被引量:4
16
作者 Ling-yan Kong Zheng-yu Jin +5 位作者 Shu-yang Zhang Zhu-hua Zhang Yi-ning Wang Lan Song Xiao-na Zhang Yun-qing Zhang 《Chinese Medical Sciences Journal》 CAS CSCD 2009年第3期156-160,共5页
Objective To assess lumen visibility of coronary stents by 64-slice computed tomography (CT) coronary angiography, and determine the value of 64-slice CT in non-invasive detecting of in-stent restenosis after coro... Objective To assess lumen visibility of coronary stents by 64-slice computed tomography (CT) coronary angiography, and determine the value of 64-slice CT in non-invasive detecting of in-stent restenosis after coronary artery stent implantation. Methods Totally, 60 patients (54 males, aged 57.0±12.7 years) and /05 stents were investigated by 64-slice CT at a mean interval of 20.0±16.6 months after coronary stents implantation. Axial multi-planar reconstruction images of the stents and curved-planar reconstruction images through the median of the stents were reconstructed for evaluating stent image quality on a 5-point scale (1=excellent, 5=nonassessable), and stent lumen diameter was detected. Conventional coronary angiography was performed in 18 patients, and 32 stents were evaluated. Results Image quality was good to excellent on average (score 1.71±0.76). Stent image quality score was correlated to heart rate (r=0. 281, P〈0.01) and stent diameter (r=-0.480, P〈0.001). All the stents were assessable in lumen visibility with an average visible lumen diameter percentage of 60.7%±13.6%. Visible lumen diameter percentage was correlated to heart rate (r=-0.193, P〈0.05), stent diameter (r=0.403, P〈0.001), and stent image quality score (r=-0.500, P〈0.001). Visible lumen diameter percentage also varied depending on the stent type. In comparison with the conventional coronary angiography, 4 of 6 in-stent stenoses were correctly detected. The sensitivity and specificity for the detection of in-stent stenosis were 66.7% and 84.6%, respectively. Conclusions Using a 64-slice CT, the stent lumen is partly visible in most of the stents. And 64-slice CT may be useful in the assessment of stent patency. 展开更多
关键词 coronary artery in-stent restenosis computed tomography
在线阅读 下载PDF
CORONARY ANGIOGRAPHY WITH DUAL SOURCE COMPUTED TOMOGRAPHY:INITIAL EXPERIENCE 被引量:4
17
作者 Zhu-hua Zhang Zheng-yu Jin +12 位作者 Shu-yang Zhang Song-bai Lin Dong-jing Li Ling-yan Kong Yi-ning Wang Lan Song Yun Wang Wen-min Zhao Wen-bin Mou Li-ren Zhang Wen-ling Zhu Qi Miao Qi Fang 《Chinese Medical Sciences Journal》 CAS CSCD 2007年第4期205-210,共6页
Objective To explore the scan technique and image quality of coronary angiography with dual source computed tomography(CT) without oral metoprolol preparation.Methods Plain and enhanced dual source CT coronary angiogr... Objective To explore the scan technique and image quality of coronary angiography with dual source computed tomography(CT) without oral metoprolol preparation.Methods Plain and enhanced dual source CT coronary angiography without oral metoprolol preparation was prospectively performed in 600 patients.Calcium scoring with plain scan images as well as multi-planar reconstruction(MPR),maximum intensity projection(MIP),and volume rendering technique(VRT) reconstruction with enhanced scan images were performed in all cases.The scan technique and post-reconstruction experience was summarized.The image quality was classified as 1 to 4 points,and coronary segments classified according to the American Heart Association standards were evaluated.Results The average calcium score of the 600 cases was 213.6±298.7(0-3 216.5).The average heart rate of the enhanced scan was 82.1±16.2(47-139) bpm.The post-reconstruction methods with which coronary segments could be shown as best as possible consisted of single phase reconstruction method,two or more phases supplemented method,and electrocardiogram editing method.Altogether 8 457 coronary segments were evaluated,among which 97.2% were evaluated as point 1,1.7% point 2,0.5% point 3,and 0.6% point 4.The coronary segments in 261 cases were completely normal,while 360 segments were diagnosed with <50% stenosis and 625 segments with ≥50% stenosis.Conclusions Excellent coronary artery image can be obtained with dual source CT in patients with any heart rate without oral metoprolol preparation.Heart rate is not a major source of the artifact,coronary segments can be well shown with single or multiple-phase reconstruction method. 展开更多
关键词 computed tomography coronary angiography coronary heart disease
在线阅读 下载PDF
Computed tomography angiography-negative aortic dissection in a patient using Phencyclidine 被引量:3
18
作者 Daniel DeWeert Elise Lovell Samir Patel 《World Journal of Emergency Medicine》 SCIE CAS 2018年第2期144-148,共5页
Although the average age of diagnosis for aorticdissection is 63,[1] this case demonstrates the need toconsider AD in younger patients, particularly in thepresence of risk factors or in the absence of anotherreasonabl... Although the average age of diagnosis for aorticdissection is 63,[1] this case demonstrates the need toconsider AD in younger patients, particularly in thepresence of risk factors or in the absence of anotherreasonable diagnosis. This case suggests PCP use as aprecipitant for hypertension and sympathomimetic stresson the aorta. Despite high sensitivity, false negativeCTA imaging for AD can occur. If pretest probabilityremains high, further imaging must be obtained. Duringresuscitation in the ED, focused point-of-care ultrasoundcan also assist with medical decision making. 展开更多
关键词 computed tomography angiography-negative aortic dissection a patient using Phencyclidine
在线阅读 下载PDF
High-resolution computed tomography in patients with atypical 'cardiac' chest pain: a study investigating patients at 10-year cardiovascular risks defined by the Framingham and PROCAM scores 被引量:1
19
作者 Choon Kiat ANG Alan Yean Yip FONG +6 位作者 Sze Piaw CHIN Tiong Kiam ONG Seyfarth M Tobias Chee Khoon LIEW Rapaee ANNUAR Houng Bang LIEW Kui Hian SIM 《Journal of Geriatric Cardiology》 SCIE CAS CSCD 2006年第1期17-21,共5页
Background and objective Atypical 'cardiac' chest pain (ACCP) is not usually caused by myocardial ischaemia. Current noninvasive investigations for these symptoms are not yet as accurate as invasive coronary a... Background and objective Atypical 'cardiac' chest pain (ACCP) is not usually caused by myocardial ischaemia. Current noninvasive investigations for these symptoms are not yet as accurate as invasive coronary angiography. The latest 64-row multi-detector computed tomography (MDCT) technology is non-invasive, has high specificity and negative predictive values for the detection of significant coronary disease. Our aim was to investigate if this modality can provide more information in the assessment of outpatients with ACCP in addition to established cardiovascular risk scores. Methods Seventy consecutive patients presenting to the outpatient clinic with ACCP underwent 64-row MDCT scan of the coronary arteries. They were categorized into low, medium or high risk groups based upon the Framingham and PROCAM scores. We defined a clinically abnormal MDCT scan as coronary stenosis =50% or calcium score >400 Agatston. Results Fifty-three (75.7%) patients did not have clinically abnormal scans. Framingham score classified 43 patients as low-risk while PROCAM classified 59 patients as low-risk. MDCT scans were abnormal for 18.6% and 22.0% of the respective low-risk group of patients. For patients with medium-to-high risk, 33.3% and 36.4% of Framingham and PROCAM patient groups respectively had abnormal MDCT scans. Conclusion MDCT adds valuable information in the assessment of patients with ACCP by identifying a significant proportion of patients categorized as low-risk to have underlying significant coronary stenosis and coronary calcification by established cardiovascular risk scores. 展开更多
关键词 multi-detector computed tomography ATYPICAL 'cardiac' CHEST pain coronary artery disease risk stratification
在线阅读 下载PDF
FINDINGS OF CHEST RADIOGRAPH AND SPIRAL COMPUTED TOMOGRAPHY IN SWYER-JAMES SYNDROME 被引量:1
20
作者 He-shui Shi Fan Yang Ping Han Jin-long Zheng Gan-sheng Feng Yong-hua Liu Zhi-liang Tian Gang Liu 《Chinese Medical Sciences Journal》 CAS CSCD 2006年第1期53-56,共4页
Objective To evaluate the value of X-ray and spiral computed tomography (SCT) in the diagnosis of Swyer-James syndrome (SJS).Methods A total of 28 patients, 12 males and 16 females, were studied retrospectively.Ages r... Objective To evaluate the value of X-ray and spiral computed tomography (SCT) in the diagnosis of Swyer-James syndrome (SJS).Methods A total of 28 patients, 12 males and 16 females, were studied retrospectively.Ages ranged from 11 to 57 years, the mean age was 32 years.All patients underwent inspiratory chest X-ray films, 5 with expiratory chest films and 1 with bronchogram.Furthermore, inspiratory and expiratory SCT scans were performed.The SCT findings were analyzed and compared with X-ray films.Results SCT demonstrated 56 lobes with hyperlucency and diminished vascularity.The size of 51 lobes were smaller and 5 were normal.X-ray films showed that hyperlucency was only in 29 lobes, in which 19 lobes were small-sized and the other 10 lobes normal.There were 56 lobes with air-trapping on expiratory SCT scans, but only 5 lobes with air-trapping on expiratory X-ray films.Bronchogram in 1 case demonstrated bronchiectasis and bronchiolitis obliterans.SCT showed 24 patients with bronchiectasis, 9 patients with tuberculosis, 10 patients with bronchiolitis, and 2 with segmental collapse.Conclusion SCT scan is superior to chest radiography in the diagnosis and differential diagnosis of SJS. 展开更多
关键词 EMPHYSEMA LUNG computed tomography Swyer-James syndrome
在线阅读 下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部