摘要
通过学习现行《建筑抗震设计规范》(GB 5 0 0 1 1— 2 0 0 1 )关于抗震节点设计的条文 ,总结出了在多层和高层钢结构房屋梁 柱刚性连接节点设计中需掌握的几个要点 ,包括 :连接设计的正确方法、为确保梁端塑性铰的形成需采取的构造措施等 ,对规范中存在的问题进行了分析 。
Through studying regulations for design of connection in Code for seismic design of Buildings (GB50011—2001),the points are summarized that must be grasped with designing the beam column rigid joint for tall building frame,such as the correct design way, aseismic checking computations,connection of plastic hinge of beam end etc. The problems in the code are analyzed,and some suggestions are presented about this kind of joint design.
出处
《建筑结构》
CSCD
北大核心
2003年第9期3-7,共5页
Building Structure
关键词
多高层房屋
钢结构
梁
柱
刚性节点
抗震设计
beam column rigid joint
seismic adjustment coefficients
plastic hinges
ductility
aseismic computations