摘要 为了提高活性炭纤维对二氯甲烷气体的吸附回收性能,我们通过二次活化的方法制备出一系列的活化后样品,并表征其基本性质。二次活化样品对二氯甲烷的静态吸附实验表明,800℃活化60 min所得样品的吸附容量最高;之后又采用自制的溶剂回收吸附装置对其进行动态吸附实验,结果显示,在100%含水率条件下,其动态吸附量比原ACF提高了40%。这表明了二次活化能够大幅提升ACF对二氯甲烷的吸附性能。为了探究吸附性能提升的原因,又通过氮吸附的方法对二次活化样品和原样品进行孔径分析,结果显示,800℃活化60 min所得样品的BET比表面积提升了47.1%,对吸附二氯甲烷起主要作用的微孔孔容提高了77.6%。 In order to improve the adsorption and recovery performance of dichloromethane gas on activated carbon fiber(ACF),a series of samples were prepared by the method of second activation and their basic properties were characterized.Static adsorption experiments show that ACF60 has the highest adsorption capacity for dichloromethane.The performance of dynamic adsorption was valuated by self-made solvent recovery column.The results show that the dynamic adsorption capacity increased by 40%.It indicates that the secondary activation can significantly enhance the activated carbon fiber's performance for the adsorption of dichloromethane gas.In order to explore the reasons of increased adsorption,the products were characterized by nitrogen adsorption.The results show that ACF60's BET specific surface area improved by 47.1% and the micropore volume that plays a major role for adsorption of dichloromethane gas increased by 77.6%.
出处 《环境工程学报》 CAS CSCD 北大核心 2014年第5期2035-2039,共5页 Chinese Journal of Environmental Engineering
基金 济宁碳素集团资助项目(MB201311080301)
关键词 二次活化 活性炭纤维 二氯甲烷 溶剂回收 secondary activation activated carbon fiber dichloromethane solvent recovery
  • 相关文献

同被引文献80

  • 1李锻,刘江江,吴彦,李国锋,王宁会.针-板式流光放电结合脉冲电源降解甲苯[J].北京理工大学学报,2005,25(z1):230-233. 被引量:3
  • 2郭智慧,祁蕾,李黎明,余江.离子液体脱氨新工艺探究[J].化工进展,2011,30(S1):587-590. 被引量:1
  • 3林先平.活性炭纤维吸附回收尾气中的环己烷[J].硫磷设计与粉体工程,2004(6):28-30. 被引量:3
  • 4曹玉春,严建华,李晓东,陈彤,岑可法.垃圾焚烧炉中二噁英生成机理的研究进展[J].热力发电,2005,34(9):15-20. 被引量:19
  • 5李雪辉,赵东滨,费兆福,王乐夫.离子液体的功能化及其应用[J].中国科学(B辑),2006,36(3):181-196. 被引量:42
  • 6Lu H F, Cao J J, Zhou Y, et al. Novel hydrophobic PDVBAR- SiO2for adsorption of volatile organic compounds from highly humid gas stream [J]. Journal of Hazardous Materials, 2013,262: 83 90.
  • 7Baur G B, Beswick O, Spring J, et al. Activated carbon fibers for efficient VOC removal from diluted streams: the role of surface functionalities [J]. Adsorption, 2015,21(4):255-264.
  • 8Zhu T, Lu L, Zhou H, et al. Advances in biopurification technology of VOCs [J]. Journal of Pure and Applied Microbiology, 2013,7(3):2073-2078.
  • 9Lu H F, Zhou Y, Han W F, et al.High thermal stability of ceria-based mixed oxide catalysts supported on ZrO2for toluene combustion [J]. Catalysis Science & Technology, 2013,3(6): 1480-1484.
  • 10Balanay J A G, Floyd E L, Lungu C T.Breakthrough curves for toluene adsorption on different types of activated carbon fibers: application in respiratory protection [J]. The Annals of Occupational Hygiene, 2015,59(4):481-490.