摘要
首先,介绍了托板上水平方向施工冷缝对无梁楼盖顶板抗冲切承载力的不利影响,列举了3个不同地区地下车库坍塌的工程实例。其次,介绍了容易导致无梁楼盖顶板的托板或相似部位出现水平施工冷缝的3种情况。最后,给出了对投入使用的无梁楼盖结构加强日常检查的建议,一旦发现托板部位存在竖向折断裂缝,应立即采取应急措施以防止坍塌事故的发生。
Firstly,the adverse effect of horizontal construction cold joint on the punching shear bearing capacity of flat slab floors were introduced.Three engineering examples of underground garage collapse in different areas were also listed.Secondly,three conditions that were easy to lead to horizontal construction cold joints in the drop panel of the flat slab floor or similar parts were introduced.Finally,the suggestions on strengthening the daily inspection of the no beam floor structure put into use was given.Once the vertical fracture cracks were found in the drop panel,emergency measures should be taken immediately to prevent the collapse accident.
作者
惠擎宇
冷涛
王满生
吴超
HUI Qing-yu;LENG Tao;WANG Man-sheng;WU Chao(China Railway Fifth Survey and Design Institute Group Co.,Ltd.,102627,Beijing,China;Beijing Institute of Housing and Urban Rural Construction Science and Technology,100021,Beijing,China;Beijing Northland Construction Engineering Co.,Ltd.,100077,Beijing,China)
出处
《建筑技术》
2024年第2期247-251,共5页
Architecture Technology
关键词
无梁楼盖
托板
柱墩
施工冷缝
施工缝
flat slab floor
drop panel
column pier
construction cold joint
construction joint
作者简介
惠擎宇(1982-),男,河北辛集人,高级工程师,硕士,e-mail:66594347@qq.com.