期刊文献+

给水泵变频改造控制策略优化 被引量:2

Optimization of Control Strategy for Frequency Conversion Transformation of Feed Water Pump
在线阅读 下载PDF
导出
摘要 为了减少电厂电动给水泵的电能消耗,实现企业节能减排的目的,对两台电动给水泵进行了变频改造,设计了相关的闭锁逻辑和自动调节逻辑。在正式投运前需要对变频系统和联锁系统进行全面试验,给出了自动控制扰动试验、抢水试验和RB试验的试验方案。 In order to reduce the power consumption of the electric feed pump in the power plant and realize the purpose of energy conservation and emission reduction,the frequency conversion transformation of two electric feed pumps is carried out,and the relevant locking logic and automatic regulation logic are designed.Before the formal operation,the frequency conversion system and interlocking system need to be comprehensively tested,and the test schemes of automatic control disturbance test,water grab test and RB test are given.
作者 康晓华 KANG Xiao-hua(Shanxi Xingneng Power Generation Co.,Ltd.,Gujiao 030206,China)
出处 《机械工程与自动化》 2022年第3期205-206,208,共3页 Mechanical Engineering & Automation
关键词 给水泵 控制策略 变频改造 feed pump control strategy frequency conversion transformation
作者简介 康晓华(1978-),男,山西代县人,工程师,本科。