基于B型剩余电流检测的交流充电桩RCD研究 被引量:4

Research on RCD of AC Charging Pile Based on Type B Residual Current Detection
在线阅读 下载PDF
导出
摘要 2020年新能源充电桩被纳入新基建行列,我国充电桩行业迎来高速发展。面对行业目前运维成本高、无人值守导致的安全隐患、安全类信息无法实时监测等问题,有必要研究一套对充电桩定位及安全类信息进行监测的系统。交流充电桩的充电控制与保护,剩余电流动作保护电器成为其关键性器件。基于传统剩余电流动作保护电器,提出了一种基于北斗授时定位、可检测B型剩余电流信息数据的智能物联网断路器,并通过云平台网页进行实时监测、智能化精准定位与安全状态信息监测管理,从而解决了交流充电桩漏电保护方面不足、运维难、无人值守和人工成本高等问题。 In 2020,new energy charging piles will be included in the ranks of new infrastructure construction,and my country’s charging pile industry will usher in rapid development.In the face of the industry’s current high operation and maintenance costs,potential safety hazards caused by unattended operations,and the inability to monitor safety information in real time,it is necessary to develop a system for monitoring charging pile positioning and safety information.The charging control and protection of AC charging piles,and the residual current action protection electrical appliances have become its key components.Based on the traditional residual current operation to protect electrical appliances,a smart IoT circuit breaker based on Beidou timing positioning and detecting type B residual current information data is proposed,and real-time monitoring,intelligent precise positioning and safety status information monitoring are carried out through the cloud platform webpage.Management,thus solving the problems of insufficient leakage protection of AC charging piles,difficult operation and maintenance,unattended operation,and high labor costs.
作者 邓志伟 谢三军 邬小可 朱佳超 DENG Zhi-wei;XIE San-jun;WU Xiao-ke;ZHU Jia-chao(State Grid Yingtan Electric Power Supply Company,Yingtan 335000,China)
出处 《电力电子技术》 CSCD 北大核心 2021年第6期56-60,共5页 Power Electronics
基金 充电桩安全在线监测关键技术研究项目(5218J018003Z)。
关键词 充电桩 剩余电流 断路器 charging pile residual curren circuit breaker
作者简介 邓志伟(1980-),男,工程师,研究方向为充电桩检测。
  • 相关文献

参考文献3

二级参考文献15

共引文献21

同被引文献22

引证文献4

二级引证文献10

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部