摘要 综述了近些年基于固定化核酸适体的光学传感器的开发与应用进展;阐述了光学适体传感器在构建过程中涉及到的核酸适体的筛选以及光纤、电极、石墨烯等载体的表面修饰、适体分子的固定等关键技术;归纳总结了一些典型光学适体传感器在生物小分子、大分子以及肿瘤标志物检测中的应用实例,对该类传感器未来的应用领域及发展趋势进行了展望。 This paper reviewed the development and the application of optical biosensor systems based on immobilized aptamers in the past several years,and presented the key technologies for the fabrication of optical aptamer sensors( OTS), involving in the screening of the aptamers, the modification of the surface of the sensor substrates( fiber,electrode,graphene and other materials etc.) and the immobilization of aptamers etc. Also,there enumerated some specific applications of OTS for the detection of biological small molecules,macro-molecules and tumor biomarkers. Finally,the prospects of application areas and development trends of OTS were analyzed.
出处 《重庆理工大学学报(自然科学)》 CAS 2017年第12期130-135,139,共7页 Journal of Chongqing University of Technology:Natural Science
基金 国家自然科学基金资助项目(61575035)
关键词 光学适体传感 医学检测 核酸适体 肿瘤标志物 optical aptamer sensing medical detection aptamers tumor biomarkers
作者简介 姚继阳(1988-),男,硕士研究生,主要从事生物医学检测技术及传感器研究,E-mail:jiyangyao@qq.com。
  • 相关文献

参考文献9

二级参考文献102

  • 1严馨蕊,高绪文,姚立红,张智清.应用核酸适配子检测细胞因子的新方法-ELONA法[J].生物工程学报,2004,20(5):679-682. 被引量:7
  • 2汪林,王成龙,储冰峰,邵宁生,杨光,董洁,高亚萍.磁珠-流式细胞术SELEX技术的建立[J].中华老年口腔医学杂志,2007,5(2):104-108. 被引量:1
  • 3李飞,罗先刚,朱少丽,杜春雷,邓启凌.一种用于LSPR传感的纳米金属列阵制作方法[J].纳米技术与精密工程,2007,5(2):121-124. 被引量:5
  • 4李文章,李洁,丘克强,曾恒志.超顺磁性Fe_3O_4纳米颗粒的制备及修饰[J].功能材料,2007,38(8):1279-1281. 被引量:15
  • 5Willets K A, van Duyne tt P. Localized surface plasmon resonance spectroscopy and sensing [J]. Annual Review of Physical Chemistry, 2007, 58(1): 267-297.
  • 6Haes A J, van Duyne R P. A unified view of propagating and localized surface plasmon resonance biosensors [J]. Analytical and Bioanalytical Chemistry, 2004, 379(7/8): 920-930.
  • 7J ensen T R, Malinsky M D, Haynes C L, et al. Nanosphere lithography: Tunable localized surface plasmon resonance spectra of silver nanoparticles [J]. Journal of Physical Chemistry B, 2000, 104(45) : 10549-10556.
  • 8Chau L K, Lin Y F, Cheng S F, et al. Fiber-optic chemi- cal and biochemical probes based on localized surface plasmon resonance [J]. Sensors and Actuators B: Chemical, 2006, 113(1) : 100-105.
  • 9Sai V V R, Kundu T, Mukherji S. Novel U-bent fiber optic probe for localized surface plasmon resonance based biosensor [J].Biosensors and Bioelectronics, 2009, 24 (9) : 2804-2809.
  • 10Viets C, Hill W. Comparison of fibre-optic SERS sensors with differently prepared tips[J]. Sensors and Actuators B: Chemical, 1998, 51(1/2/3) : 92-99.

共引文献27

同被引文献7

引证文献1

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部