摘要 目的:建立测定复杂用药环境下人血清中替考拉宁浓度的反相高效液相色谱法。方法:色谱柱为Agilent ZORBAX SB-C_(18)柱(250mm×4.6mm,5μm),流动相为乙腈-0.02mol·L^(-1)的NaH_2PO_4溶液(24∶76,H_3PO_4调pH值为2.02),流速1.0mL·min^(-1),检测波长240nm,柱温28℃。结果:替考拉宁在2.01~80.67μg·mL^(-1)(r=0.998 9,n=7)范围内浓度与校正因子f(替考拉宁峰面积/哌拉西林的峰面积)成良好的线性关系,定量限为50.5ng,替考拉宁平均提取回收率为87.17%,方法平均回收率为100.7%,(RSD=1.93%,n=9)。结论:该法操作简便、灵敏、准确,适用于替考拉宁血药浓度的测定。 OBJECTIVE To establish a RP-HPLC method for determination of teicoplanin in serum in complicated condi- tions. METHODS An Agilent ZORBAX SB-Cls column was used as the chromatographic column, the mobile phase consisted of a mixture of acetonitrile-0. 02 mol. L-1 Nail2 PO4 (24:76, pH was adjusted to 2. 02 with H3 PO4 ). The flow rate was 1 mL. min-1 , the detection wavelength 240 nm, and column temperature 28 ℃. RESULTS There was a good linear relationship be- tween the concentration of teicoplanin and correction factor (f, peak area value of teicoplanin/peak area value of piperacillin) within the range of 2. 01 - 80. 67 g· mL- 1 (r = 0. 998 9, n = 7), limit of quantitation was 50. 5 ng. The average extraction recov- ery was 87. 17 %, and the average method recovery was 100. 7 % (RSD = 1.930%, n = 9). CONCLUSION The method is sim- ple, sensitive and accurate, which can be used for the assay of teicoplanin in serum under complicated conditions.
出处 《中国医院药学杂志》 CAS 北大核心 2017年第12期1163-1166,共4页 Chinese Journal of Hospital Pharmacy
基金 河南省医学科技攻关计划项目(编号:201602333)
关键词 替考拉宁 反相高效液相色谱法 血药浓度 teicoplanin RP-HPLC serum concentration
作者简介 何勐,男,主管药师,研究方向:药物分析,电话:0371—67690286,E-mail:hemeng053@163.com [通讯作者]周丽娟,女,副主任药师,研究方向:药物新技术和药物分析学,电话:0371-67690341,E-mail:zhou750423@126.com
  • 相关文献

参考文献7

二级参考文献73

共引文献95

同被引文献61

引证文献14

二级引证文献36

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部