期刊文献+

新疆强风沙尘环境下750kV线路运维技术 被引量:13

Operation and maintenance techniques for 750 kV transmission lines under severe wind and sand-dust weather in Xinjiang
在线阅读 下载PDF
导出
摘要 为了保证大风及强沙尘环境下特高压输电线路的正常运维,确保输电线路及电网安全,针对750 kV特高压输电线路提出了防范强风沙尘侵害的措施。通过总结新疆地区气象特征,分析新疆电网输电线路在强风沙尘作用下可能出现的故障现象,从防范绝缘子伞裙破裂、金具和引流线磨损等方面给出了具体的技术方法。结合新疆750 kV输电线路实际发生的故障案例以及故障处置对策,说明了该方法对于提升750 kV特高压输电线路的耐受强风沙尘能力是有效和实用的,可为后续强风沙尘地区的输电线路设计及高可靠性运行提供有益借鉴。 To ensure the normal operations of UHV transmission lines under strong wind and sand-dust conditions and the safety of transmission line and power grid,the prevention measures to encroachments by strong wind and sand-dust are presented in allusion to the 750 kV UHV transmission lines.Through summarizing the meteorological characteristics of Xinjiang region and analyzing the fault events that may occur in transmission lines of Xinjiang power grid under the effect of strong wind and sand-dust conditions,including the particular technical methods to prevent from shed skirt fracture of insulator,wear and tear of metal fittings and jumper conductors of UHV transmission lines,etc.Combining with some actual fault cases and the corresponding fault disposal measures of 750 kV transmission line in Xinjiang,it shows that this method is practical and effective in improving the ability of enduring strong wind and sand-dust conditions for 750 kV UHV transmission lines,and can be used in future design and provide valuable reference for transmission lines operating with high reliability in strong wind and sand-dust area.
出处 《电力系统保护与控制》 EI CSCD 北大核心 2017年第2期123-130,共8页 Power System Protection and Control
关键词 气象灾害 线路故障 运行维护 强风 沙尘 meteorological disaster transmission line fault operation maintenance strong wind sand-dust
作者简介 李娟(1978-),女,高级工程师,从事电力系统设计技术研究和管理工作; 廖峥(1991-),男,通信作者,硕士研究生,研究方向为电网气象灾害风险评估与预警;E—mail:leocqu@foxmail.com 张陵(1969-),男,硕士,高级工程师,从事电力系统运维检修技术研究和管理工作。
  • 相关文献

参考文献17

二级参考文献164

共引文献208

同被引文献193

引证文献13

二级引证文献104

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部