期刊文献+

一种改进的10kV开关柜局部放电TEV检测及定位技术 被引量:17

An Improved TEV Detection and Location Technique of Partial Discharge for 10 kV Switchgear
在线阅读 下载PDF
导出
摘要 介绍了通过测量暂态地电压来检测10 kV高压开关柜内部局部放电的基本原理及目前常用的检测仪器,分析了应用中存在的主要问题,并提出了改进方法。依据改进方法组建了便携式检测系统,包括双通道探头、高速采集卡及上位机处理软件等,实现了地电波波形的采集、显示、波形分析及信号时间差的确定。应用该系统进行局部放电源的定位,验证了该改进方法的有效性。 The principle of partial discharge of 10 kV Switchgear detected by transient earth voltage(TEV) method and common instruments were introduced, and some existing problems in application wereanalyzed, and an improved technique was proposed. A portable detection system including two-channelprobes, data acquisition card and PC software, was established according to the improved method, whichcan realize the collection, display and analysis of the TEV waveform and the determination of time differenceof signal. It is proved that the improved detection system is effective to locate the partial dischargesource.
出处 《绝缘材料》 CAS 北大核心 2014年第2期93-96,101,共5页 Insulating Materials
关键词 10KV开关柜 局部放电 地电波 10 kV Switchgear partial discharge TEV waveform
作者简介 邓雨荣(1965-),男(汉族),广西桂林人,教授级高级工程师,主要从事电力系统过电压试验研究工作; 田树军(1972-),男(土家族),湖北省来凤县人,高级工程师,主要从事电力系统过电压试验研究工作.
  • 相关文献

参考文献12

二级参考文献41

共引文献389

同被引文献116

引证文献17

二级引证文献48