摘要
在烟气处理量为50 000 m3/h的电袋复合除尘试验台上研究了静电场、过滤风速、粉尘浓度等因素对电袋复合除尘器运行特性的影响。结果表明:静电场可以除去烟气中的大部分粉尘,大大降低袋式除尘单元负荷,延长清灰周期,使布袋使用寿命得到延长;过滤风速和粉尘浓度主要影响电袋除尘器的运行阻力,对除尘效率基本没有影响。
On the test stand of a combined dust collector being composeo of electrostatic precipitator and bag type filter,and having a flue gas disposal capacity of 50 000 m3/h,the influence of factors,such as static electric field, air velocity for filtering, and dust concentration etc. , upon the perfomance in opera- tion of said combined dust collector has been studied. Results show that the static electric field can re- move a large part of dust, greatly reducing the load of bag type filter,lengthening the period of dust cleaning,making the service- life of bag type filter to be lengthened; the air velocity for filtering and the dust cocentration are mainly affecting the resistance in operation of the said combined dust collec- tor,basically having no influence upon the dust removal efficiency.
出处
《热力发电》
CAS
北大核心
2011年第8期48-50,82,共4页
Thermal Power Generation
关键词
燃煤电厂
除尘
静电
袋式
复合除尘器
coal - fired power plant
dust removal
electrostatic
bag type
combined dust collector
作者简介
作者简介:邵伟(1979-),男,毕业于武汉大学,学士,工程师,兖矿济三电力公司检修车间技术主管,中国矿业大学电力学院动力工程专业在读工程硕士。E—mail:swei_jsdc@163.com