摘要
本法用微波消化植物样品,通过正交试验分析获得较优的微波消化条件,用此条件对锌、铁、锰元素作添加回收试验,得回收率分别为97.0%、94.3%、90.6%,变异系数分别为1.2%、4.1%、3.4%。另外,该法与国标法相比无显著性差异,通过实验分析得出...
A microwave technique for digiestion of plant samples was pretented.Better digestion condition was obtained by orthogonal test.Zn、Fe、Mn elements were made to the addition and recoveries test.The method gave recoveries of 97.0%,94.3%,90.6%,variation coefficient of 1.2%,4.1%,3.4%,Compared with the national standards,this method is safety,simple and quick.
出处
《中国卫生检验杂志》
CAS
1999年第4期248-251,共4页
Chinese Journal of Health Laboratory Technology
关键词
原子吸收
微波消化
无花果叶
微量元素