不同膨胀系数石膏模型材料对树脂义齿表面粗糙度的影响研究 被引量:2

Influence research of different expansion coefficient plaster cast materials on resin denture surface roughness
在线阅读 下载PDF
导出
摘要 目的研究不同膨胀系数石膏模型材料对义齿表面粗糙度的影响。方法采用高、中、低三种不同膨胀系数的石膏模型材料,分别装埋型盒,各制作5个30 mm×10 mm×6.0 mm的树脂基托试样,测量其表面粗糙度。结果高、中、低膨胀系数石膏模型材料制作树脂试样表面粗糙度:轮廓算术平均偏差(Ra)值分别为(1.64±0.23)μm,(1.08±0.13)μm,(0.65±0.23)μm;微观不平高度(Rz)值分别为(6.44±1.12)μm,(5.18±0.96)μm,(3.35±0.95)μm,差别有统计学意义(P<0.01)。结论低膨胀系数石膏模型材料制作的树脂试料表面粗糙度值最低。 Objective To evaluate the influence of different expansion coefficient plaster cast materials on denture surface roughness. Methads We compared the differences of denture surface roughness cured by three kinds of plaster east materials of different expansion eoeffidents: high, medium and low expansion coefficient. Specimens with 30mm× 10mm× 6.0mm were made for measuring surface ronghness. Results Specimens invested on high, medium and low expansion coefficient got the surface roughness Ra: ( 1.64 ± 0.23) μm, ( 1.08 ± 0.13) μm, (0.65 ± 0.23)μm; Rz: (6.44 ± 1.12)μm, (5.18 ± 0.96)μm, (3.35 ± 0.95)μm. Those all had significant differences( P 〈 0.01 ). Conclusion The surface roughness of specimens invested for low expansion coefficient was lower than those of high expansion coefficients' and medium expansion coefficient plaster east materials.
作者 王雪 陈宜辉
出处 《口腔医学》 CAS 2008年第8期424-426,共3页 Stomatology
关键词 石膏 膨胀系数 表面粗糙度 die stone expansion coefficient surface roughness
作者简介 通信作者:王雪Tel:13361200063 E-mail:wangxue2000@tom.com
  • 相关文献

参考文献10

  • 1张小红,王雪,董文玉.不同抛光方法对钴铬合金铸件表面质量及物理性能的影响[J].口腔医学,2007,27(12):636-638. 被引量:3
  • 2姜明德,黄芝慧.公差配合与技术测量[M].湖南:湖南科学技术出版社,1985:103-114.
  • 3Kaplan BA, Goldstein GR, Vijayaraghavan TV, et al. The effect of three polishing systems on the surface roughness of four hybrid composites: a profilometric and scanning electron microscopy study [ J ]. J Prosthet Dent, 1996,176( 1 ) :34 - 38.
  • 4陈治清.口腔材料学[M].3版.北京:人民卫生出版社,2003:117-118.
  • 5Derrien G. Evaluation of detail reproduction for three die material by using scanning electron microscopy and two dimensional profilomeetry [J]. J Prosthet Dent, 1995,74(1):1 -7.
  • 6寺冈文雄.辙低检证レジソ床のすて[M].东京:日本医齿乐出版株式会社,1999:96-97.
  • 7王雪,陈春霞,翟小棠,巢永烈.不同包埋方法对义齿表面粗糙度的影响[J].实用口腔医学杂志,2005,21(2):255-255. 被引量:8
  • 8Kawai K, Urano M, Ebisu S. Effect of surface roughness of porcelain on adhesion of bacteria and their synthesizing glucans[ J]. J Prosthet Dent, 2000,83(6) :664 - 667.
  • 9Patterson C J, Mclundie AC, Stirrups DR. Efficacy of a porcelain refinishing system in restoring surface finish after grinding with fine and extrafine diamondburs[ J]. J Prosthet Dent, 1992, 68(3):402 - 406.
  • 10李梅,杨圣辉,王者玲,李金陆.钛种植体基台的表面粗糙度与细菌粘附[J].中华口腔医学杂志,2001,36(6):34-36. 被引量:13

二级参考文献18

  • 1陈春霞,王雪,巢永烈.不同热加工方式对义齿树脂材料物理性能的影响研究[J].北京口腔医学,2005,13(2):83-85. 被引量:3
  • 2王雪,张小红,牟建刚,刘虹,李金华.不同抛光方法对钴铬合金铸造义齿表面粗糙度及精度的影响[J].上海口腔医学,2006,15(6):641-644. 被引量:9
  • 3姜明德 黄芝慧.公差配合与技术测量[M].湖南:湖南科学技术出版社,1985.103-114.
  • 4Noort VR,Davis LG.The surface finish of composite resin restorative materials.Br Dent J,1984,157(10):360.
  • 5Kaplan BA,Goldstein GR.The effect of three polishing systemson the surface roughness of four hybrid composite: A profilometric and scanning electron microscopy study.J Prosthet Dent,1996,76(10):34.
  • 6杨世春.表面质量与光整技术[M].北京:机械工业出版社,1999.
  • 7Quirynen M, Van der Mer HC, Bollen CIVIL, et al. An in-vivo study of the surface roughness of implants on the microbiology of supra-and subgingival plaque. Dent Res[J]. 1993,72(9) :1304 - 1309.
  • 8姜明德,黄芝慧.公差配合与技术测量[M].湖南:湖南科学技术出版社,1985:103-114.
  • 9Lia R, Silvia F, Eugenio B, et al.The effect of surface roughness on early in vivo plaque colonization on titanium[J] .J Periodontol, 1997,68 (6) :556 - 562.
  • 10廖海珠.义齿磨光的粗糙度标准及其所需的线速度问题.临床口腔医学杂志,1985,1(3):164-166.

共引文献38

同被引文献26

引证文献2

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部