摘要
建立阿司匹林贴剂含量的测定方法。乙腈为阿司匹林贴剂的萃取溶剂,用Waters公司SymmetryShieldTMRP18柱(3.9mm×150mm,5μm),流动相乙腈0.01mol·L-1的磷酸氢二钠(磷酸调pH值至2.50);体积比为25∶75;检测波长234nm;流速1.0mL·min-1。阿司匹林在3~96μg·mL-1范围内呈现良好的线性关系,r=0.9993。阿司匹林回收率为100.3%,RSD为0.42%。本方法简单、灵敏、准确,可作为该制剂内在质量的控制方法。
A method for measurement of aspirin in the patch was developed with the high performance liquid chromatography (HPLC), Acetonitrile was used as extracted solution. Symmetry Shield^TM RP18 column was adopted and the mobile phase was composed of acetonitrile-0.01 mol·L^-1 di-sodium hydrogen phosphate (adjusting pH to 2.50 with phosphoric acid). A linearity with a good correlation coefficient was yielded from 3 to 96μg · mL^-1 for aspirin (r = 0.999 3). The average recovery was 100.3% and RSD was 0.42%. This method is simple, sensitive and accurate, and can be used for the quality control of the patch.