摘要 基于锦屏二级水电站过水围堰结构和运行特征,分析了溃堰工况与风险因素,获得了溃堰洪水对锦屏二级工程自身、堰前库区至下游梯级电站范围内的河道影响程度。实例结果表明,该研究对土石过水围堰的防冲设计和溃堰洪水对下游梯级影响评估有一定指导意义。 Based on the structure and operation features of overflow cofferdam of Jinping Ⅱ Hydropower Station,the cofferdam-breaking conditions and its risk factors are analyzed.And it analyzes the influence of cofferdam-break flood on project itself and channel from the reservoir of cofferdam to the downstream cascade hydropower station.It proves by a case that the study has references for anti-scour design of overflow cofferdams and evaluation of cofferdam-break flood influencing on cascade hydropower stations.
出处 《水电能源科学》 北大核心 2011年第4期102-104,共3页 Water Resources and Power
基金 国家十一五科技支撑计划基金资助项目(2008BAB29B02) 国家自然科学基金资助项目(10902078)
关键词 溃堰 风险分析 过水围堰 锦屏二级水电站 cofferdam break risk analysis overflow cofferdam Jinping Ⅱ Hydropower Station
作者简介 作者简介:李军(1971-),男,教授级高级工程师,研究方向为水电水利工程施工组织设计,E—mail:lii3@ecidi.com